Place the back plate opposite the connector. Check that the
back plate is vertical and mark the mounting holes you wish
to use. Select holes so that it is as far away from any joints
as possible. Pre-drill the hole using an 8mm concrete drill;
the hole must be at least 80 mm deep. Clean the hole care-
fully and screw the back plate to the chimney breast using
the 4 supplied concrete screws. Screws that do not tighten
must be considered useless and be moved to new holes.
Insert the connection pipe into the wall connector
towards the folded tabs.
Ø 8 mm
50 mm
Check that the pipe protrudes 50 mm from the back plate and caulk between
the connection pipe and the connector in the wall using caulking rope. If
further sealing material is required, heat-resistant sealant may be used
Assembling the stove