Installation distance to walls and ceiling
100
A 63
0
680
495
max Ø154
520
2000
Brændbart loft
420
135
D 20
B 510
C 65
max Ø154
390
15
0
84
0
Min. 3
70
73
5
Combustible wall
Constructional
Hearth
28
0
15
0
Min. 3
70
500
745
200
300
400
18
0
28
0
380
Combustible wall
Permitted area for combustible material
Constructional
Hearth
29
0
50
700
Min. 3
70
635
Fire-retardant wall of
brick or concrete
Constructional
Hearth
18
0
50
Min. 3
70
50
295
Fire-retardant wall of
brick or concrete
Constructional
Hearth
A =
height from floor to top flue connection
B =
height from floor to c/c smoke outlet rear
C =
distance from back to c/c air inlet, Ø64
D =
distance from back to smoke outlet rear
28
0
15
0
500
745
100
200
300
400
80
18
0
28
0
380
Sallittu alue tulenaralle materiaalille.
Tulenarka seinä
Combustible ceiling
Permitted area for combustible material.
INSTALLATION DISTANCES
C51L
Move the stove in position and check that the installation distances given in the diagrams are met. The minimum distance between
the stove opening and combustible parts of the building or décor must be at least 1 m.
When top connecting a steel flue please refer to the relevant manufacturer’s installation instructions. Observe the safety distances
to combustible material that steel flues require.