Contura C 51L Скачать руководство пользователя страница 4

GB

4

General

This manual contains instructions about how Contura 51L must be 
assembled and installed. 

To guarantee the function and safety of the stove we recommend 
that it is installed by a professional. Our Contura agents can 
recommend a suitable installer.

The stove is type approved and must be connected to a chimney 
dimensioned for at least 350°C, The connector on the stove 
is suitable for pipes with an inner diameter of Ø150 mm and 
an outer diameter of maximum Ø154 mm. The room or space 
containing a stove shall have a permanent air supply sufficent to 
ensure proper combustion, to determine correct amount of air 
supply use current edition of Building Regulations.

Eldstadsbeklädnad

Löstagbart handtag

Rosterreglage

Asklåda

Förbränningsluftsreglage

Brasbegränsare

Typskylt

Fire-box surround

Grate shuttle

Ash-pan

Log guard

Removable handle

940

15

0

840

175

175

370

HANDÖL

In accordance with standards below
marking was affixed:
European Standard:
SE Quality Certification, P-marked:
NO Standard NS 3059:
DE and A Standard DINplus
and Art 15a B-VG:
Type:
Nominal Output:
Fuel:
Minimun draught:
Flue gas temerature:
Energy efficiency:
Emission of CO in cumbustion products:
Distance to cumbustible wall (mm):

Production number:

Follow the installation instructions.
Use only recomended fuels
NIBE AB Box 134 SE-285 23 MARKARYD SWEDEN

2006
EN 13240
Cert no 220316
SINTEF 110-0257

RRF-40 07 1261
H51/H52/H52T
5 kW
Wood
12 Pa
275°C
79%
0,13%
Behind 150
Beside 500 
Corner 150

HANDÖL

NIBE AB SE-85 21 Markaryd Sweden

Type:

Production no.

50-series
7090300236

Type plate

Air supply control

GENERAL

Building application

Before installing a stove 
or erecting a chimney it is 
necessary for you to apply 
for planning permission 
from your local authority. 
Ask your local authority 
for advice regarding 
building regulations and the 
application.

Hearth dimensions

The stove must be placed on a constructional heart with the 
minimum dimensions shown beside, installations distances 
must also be according to diagrams on next page.  Check that 
the building has enough bearing capacity for the heart, stove 
and chimney. The stove can be loaded with maximum 100 kg of 
chimney.

Chimney

Note!

 The stove installation and connection to a chimney must 

be accomplished with the current edition of Building Regulations. 
We recommend that you consult a local chimney sweep before the 
installation to make sure that the chimney is in good condition.

The stove requires a draught in the chimney of at least –12 
Pa. The draught is affected both by the length and area of the 
chimney, and by how well sealed it is. Minimum recommended 
chimney length is 3.5 m and a suitable cross section area is 
150-200 cm² (140-160 mm in diameter). Carefully check that 
the chimney is sealed and that there is no leakage around soot 
hatches and flue connections.

Note that a flue with sharp bends and horizontal routing reduces 
the draught in the chimney. Maximum horizontal flue is 1 m, 
on the condition that the vertical flue length is at least 5 m. It 
must be possible to sweep the full length of the flue and the soot 
hatches must be easily accessible.

Technical data

Output   

4 kW

Nominal output 

5 kW

Efficiency level 

79%

Model  

C51L

Weight (kg) 

124

Width (mm) 

495

Depth (mm) 

420

Height (mm) 

630

The connector’s inner diameter is Ø154 mm
Type approved in accordance with:
European standard EN-13240 
Swedish environmental and quality marking, 
Swan marked No 378 001 and
P-marking cert. no. 22 03 16
(N) NS 3059, Cert.nr SINTEF 110-0257
(DE/A) DINplus, Art. 15a B-VG RRF-40 07 1261

DEFRA exempted

The stove can be used in Smoke Control Areas. Smouldering, i.e. 
reduced air supply, are prevented by blocking the combustion 
damper of 4 kW output.

Содержание C 51L

Страница 1: ...Installation Lighting INSTRUCTIONS C 51L www contura eu...

Страница 2: ...Niklas Gunnarsson Business area manager NIBE STOVES Manufacturer s assurance The stove is approved by the Swedish National Testing and Research Institute SP SITAC and fulfils the applicable rules for...

Страница 3: ...o best light your stove in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the stro...

Страница 4: ...hority Ask your local authority for advice regarding building regulations and the application Hearth dimensions The stove must be placed on a constructional heart with the minimum dimensions shown bes...

Страница 5: ...flue connection B height from floor to c c smoke outlet rear C distance from back to c c air inlet 64 D distance from back to smoke outlet rear 280 150 500 745 100 200 300 400 80 180 280 380 Sallittu...

Страница 6: ...Fire box surround When sweeping the smoke baffle must be lifted out this can be done when one side has been dismantled Fire bars Lift the fire bars straight up clean the ash from the guide groove in t...

Страница 7: ...fted out when all the cladding has been removed Fixed or removable handle The stove handle is fitted on delivery To make the handle removable replace the screw for the lock hook with the shorter screw...

Страница 8: ...nnection on delivery When connecting from the rear the cover and connection must be swapped around Dismantle the cladding as instructed previously see page 6 7 Tap out the knock out in the stove s bac...

Страница 9: ...out Put stove cement inside the flue connection and press the start pipe into the connection Continue the chimney installation according to the chimney installation instructions max 154 CHIMNEY Adjus...

Страница 10: ...s for controlling combustion vary depending on the temperature in the stove and the draft in the chimney 4 The lowest output of 4 kW is usually obtained when the combustion damper is 30 open and two l...

Страница 11: ...n an environmentally adapted stove with high efficiency also means lower wood consumption to heat the home The Swan mark makes it easy for you to be part of building a sustainable future 378 001 N ORD...

Страница 12: ...d parts have discoloured it is due to an excessive temperature in the stove The reason for the excessive temperature can be that the maximum amount of wood has been used inappropriate fuel has been us...

Отзывы: