GB
4
General
This manual contains instructions about how Contura 51L must be
assembled and installed.
To guarantee the function and safety of the stove we recommend
that it is installed by a professional. Our Contura agents can
recommend a suitable installer.
The stove is type approved and must be connected to a chimney
dimensioned for at least 350°C, The connector on the stove
is suitable for pipes with an inner diameter of Ø150 mm and
an outer diameter of maximum Ø154 mm. The room or space
containing a stove shall have a permanent air supply sufficent to
ensure proper combustion, to determine correct amount of air
supply use current edition of Building Regulations.
Eldstadsbeklädnad
Löstagbart handtag
Rosterreglage
Asklåda
Förbränningsluftsreglage
Brasbegränsare
Typskylt
Fire-box surround
Grate shuttle
Ash-pan
Log guard
Removable handle
940
15
0
840
175
175
370
HANDÖL
In accordance with standards below
marking was affixed:
European Standard:
SE Quality Certification, P-marked:
NO Standard NS 3059:
DE and A Standard DINplus
and Art 15a B-VG:
Type:
Nominal Output:
Fuel:
Minimun draught:
Flue gas temerature:
Energy efficiency:
Emission of CO in cumbustion products:
Distance to cumbustible wall (mm):
Production number:
Follow the installation instructions.
Use only recomended fuels
NIBE AB Box 134 SE-285 23 MARKARYD SWEDEN
2006
EN 13240
Cert no 220316
SINTEF 110-0257
RRF-40 07 1261
H51/H52/H52T
5 kW
Wood
12 Pa
275°C
79%
0,13%
Behind 150
Beside 500
Corner 150
HANDÖL
NIBE AB SE-85 21 Markaryd Sweden
Type:
Production no.
50-series
7090300236
Type plate
Air supply control
GENERAL
Building application
Before installing a stove
or erecting a chimney it is
necessary for you to apply
for planning permission
from your local authority.
Ask your local authority
for advice regarding
building regulations and the
application.
Hearth dimensions
The stove must be placed on a constructional heart with the
minimum dimensions shown beside, installations distances
must also be according to diagrams on next page. Check that
the building has enough bearing capacity for the heart, stove
and chimney. The stove can be loaded with maximum 100 kg of
chimney.
Chimney
Note!
The stove installation and connection to a chimney must
be accomplished with the current edition of Building Regulations.
We recommend that you consult a local chimney sweep before the
installation to make sure that the chimney is in good condition.
The stove requires a draught in the chimney of at least –12
Pa. The draught is affected both by the length and area of the
chimney, and by how well sealed it is. Minimum recommended
chimney length is 3.5 m and a suitable cross section area is
150-200 cm² (140-160 mm in diameter). Carefully check that
the chimney is sealed and that there is no leakage around soot
hatches and flue connections.
Note that a flue with sharp bends and horizontal routing reduces
the draught in the chimney. Maximum horizontal flue is 1 m,
on the condition that the vertical flue length is at least 5 m. It
must be possible to sweep the full length of the flue and the soot
hatches must be easily accessible.
Technical data
Output
4 kW
Nominal output
5 kW
Efficiency level
79%
Model
C51L
Weight (kg)
124
Width (mm)
495
Depth (mm)
420
Height (mm)
630
The connector’s inner diameter is Ø154 mm
Type approved in accordance with:
European standard EN-13240
Swedish environmental and quality marking,
Swan marked No 378 001 and
P-marking cert. no. 22 03 16
(N) NS 3059, Cert.nr SINTEF 110-0257
(DE/A) DINplus, Art. 15a B-VG RRF-40 07 1261
DEFRA exempted
The stove can be used in Smoke Control Areas. Smouldering, i.e.
reduced air supply, are prevented by blocking the combustion
damper of 4 kW output.