Installation/Lighting
INSTRUCTIONS
C 51L
www.contura.eu
Страница 1: ...Installation Lighting INSTRUCTIONS C 51L www contura eu...
Страница 2: ...Niklas Gunnarsson Business area manager NIBE STOVES Manufacturer s assurance The stove is approved by the Swedish National Testing and Research Institute SP SITAC and fulfils the applicable rules for...
Страница 3: ...o best light your stove in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the stro...
Страница 4: ...hority Ask your local authority for advice regarding building regulations and the application Hearth dimensions The stove must be placed on a constructional heart with the minimum dimensions shown bes...
Страница 5: ...flue connection B height from floor to c c smoke outlet rear C distance from back to c c air inlet 64 D distance from back to smoke outlet rear 280 150 500 745 100 200 300 400 80 180 280 380 Sallittu...
Страница 6: ...Fire box surround When sweeping the smoke baffle must be lifted out this can be done when one side has been dismantled Fire bars Lift the fire bars straight up clean the ash from the guide groove in t...
Страница 7: ...fted out when all the cladding has been removed Fixed or removable handle The stove handle is fitted on delivery To make the handle removable replace the screw for the lock hook with the shorter screw...
Страница 8: ...nnection on delivery When connecting from the rear the cover and connection must be swapped around Dismantle the cladding as instructed previously see page 6 7 Tap out the knock out in the stove s bac...
Страница 9: ...out Put stove cement inside the flue connection and press the start pipe into the connection Continue the chimney installation according to the chimney installation instructions max 154 CHIMNEY Adjus...
Страница 10: ...s for controlling combustion vary depending on the temperature in the stove and the draft in the chimney 4 The lowest output of 4 kW is usually obtained when the combustion damper is 30 open and two l...
Страница 11: ...n an environmentally adapted stove with high efficiency also means lower wood consumption to heat the home The Swan mark makes it easy for you to be part of building a sustainable future 378 001 N ORD...
Страница 12: ...d parts have discoloured it is due to an excessive temperature in the stove The reason for the excessive temperature can be that the maximum amount of wood has been used inappropriate fuel has been us...