Contura C 34T Скачать руководство пользователя страница 4

GB

68

Effect 

3-7 kW

Nominal effect 

5 kW

Efficiency  

80%

Model C34T

 

Weight (kg) 

320

Width (mm) 

550

Depth (mm) 

430

Height (mm) 

1600

Reservoir stones (kg) 

70

Installation by authorised 
technician 

This manual contains instructions on 
how the stoves must be assembled and 
installed. To ensure the function and 
safety of the stove, we recommend that 
the installation be carried out by an 
authorised technician. Contact one of 
our dealers who can recommend suitable 
fitters. 

Building permission

Before installing a stove or erecting a 
chimney, it is necessary for you to make 
an application for building permission 
to your local authority. Ask your local 
authority for advice regarding building 
regulations and the application.

Structural support

Check that the wood joists are strong 
enough to bear the weight of the stove 
and chimney. The stove and chimney can 
usually be placed on a normal wooden 
joist in a single occupancy house, if the 
total weight does not exceed 400 kg.

Hearth plate

Due to the risk of embers falling out, a 
flammable floor must be protected by 
a hearth plate. It must extend 300 mm 
in front of the stove and 100 mm on 
each side of the stove, or have a 200 mm 
extension on each side of the opening. 
The hearth plate can consist of natural 
stone, concrete, metal plate or glass. 
A painted metal or glass hearth plate 
is available as an accessory for these 
models. 

Important to remember!

Technical details

Type approved in accordance with:
European standard EN-13240 
Swedish environmental and quality marking, 
P-marking cert. no. 0112/07
Norwegian standard NS 3059, SINTEF 110-
0275 
German standard DIN 18.891, RRF-40 09 
1945

FACTS

Eldstadsbeklädnad

Rosterreglage

Asklåda

Förbränningsluftsreglage

Brasbegränsare

HANDÖL

In accordance with standards below
marking was affixed:
European Standard:
SE Quality Certification, P-marked:
NO Standard NS 3059:
DE and AT Standard DIN 18.891 and
Art 15a B-VG:
Type:
Nominal Output:
Fuel:
Minimun draught:
Flue gas temerature:
Energy efficiency:
Emission of CO in cumbustion products:
Distance to cumbustible wall (mm):

Follow the user’s instructions and use only recomended fuel

NIBE AB Box 134 SE-285 23 MARKARYD SWEDEN

2007
EN 13240
Cert no 0112/07
SINTEF 110-0275

RRF-40 07 13 90

Handöl 31/31A/32/32A
5 kW
Wood
12 Pa
280°C
78%
0,14%
Behind 150
Beside 450 
Corner 150

HANDÖL

NIBE AB SE-85 21 Markaryd Sweden

Type:

Production no.

50-series
7090300236

Rating plate

Fire bars

Hearth cladding

Grate control

Combustion air control

Ash-pan

Содержание C 34T

Страница 1: ...Installation instructions C 34T www contura eu...

Страница 2: ...LARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 415 mm to side Other safety di...

Страница 3: ...Read how to best light your stove in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injuries if touched Also tak...

Страница 4: ...h side of the stove or have a 200 mm extension on each side of the opening The hearth plate can consist of natural stone concrete metal plate or glass A painted metal or glass hearth plate is availabl...

Страница 5: ...0 629 900 900 6 4 0 Fire retardant wall of brick or concrete 217 50 700 1100 50 325 Fire retardant wall of brick or concrete Place the stove on the hearth plate and check that the installation distanc...

Страница 6: ...t the knockout using a hammer The air duct connector on the stove has an external diameter of 64 mm In hot areas the duct has to be insulated with 30 mm mineral wool covered with a moisture barrier pl...

Страница 7: ...flector The clos ing force of the hatch can be adjusted by moving the spring between the three notches on the lever The angle of the stove also affects the closing force of the spring If the spring fo...

Страница 8: ...in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommended chimney length is 3 5 m and suitable cross secti...

Страница 9: ...con nected to the top Connection to chimney Sweeping When sweeping the smoke baffle must be removed on the Con tura 30 series this can be done by lifting the smoke baffle and removing the side piece...

Страница 10: ...F 603499 F 603496 The stones are numbered as illustrated above We recommend that the stones be installed in the order described on the fol lowing pages Take care of the soapstones They scratch easily...

Страница 11: ...GB 75 10 10 VAN ADI UM No 7 CH RO M E Do not tighten the screws 3 4 5 6 7 INSTALLATION...

Страница 12: ...LATION Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions bef...

Страница 13: ...adjustment brackets to the upper concrete screws Adjust the stone so it is aligned with the side stones along the top edge Tighten the 4 concrete screws Check that the distance between the door and to...

Страница 14: ...GB 78 Heat reservoir to soapstone top Installation of accessories Heat reservoir 1 2 3 4 INSTALLATION...

Страница 15: ......

Страница 16: ...n www contura eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contur...

Отзывы: