For this type of connection, first remove the valance 
that sits in front of the back plate's air intake.

In the case of connection through the floor, first 
remove the knockout in the guide plate and any 
hearth plate.

SUPPLY AIR/ACCESSORY

Supply of combustion air

When a stove is installed in a room, the air supply demand to the 
room increases. Air can be provided indirectly via a vent in the 
outer wall or via a duct from the outside that is connected to the 
connector on the underneath of the stove. The amount of air 
needed for combustion is approx. 25m

3

/h.

The connector has an external diameter of 67 mm. When installing 
ducts longer than 1 m, the pipe diameter must be increased to 100 
mm and a correspondingly larger wall vent must be selected. 

In hot areas, the duct should be insulated with 30 mm mineral 
wool covered with a moisture barrier (plastic). It is important that 
the lead-in, between the pipe and the wall (or floor), is sealed 
using jointing compound. 

A 1 m length of condensation-insulated ducting for combustion air 
is available as an accessory.

Installation variants

Содержание C 26T Low

Страница 1: ...Installation instructions C 26T Low www contura eu ...

Страница 2: ...ECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 600 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 09 NOx 82 mg m3 OGC 43 mg m3 PM 22 mg m3 Surface temperatures Approved Cleaning opti...

Страница 3: ...e in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injuries if touched Also take heed of the strong heat radiated through the door glass Placing flammable material closer than the safe distance indicated may cause a fire Smoulder combustion can cause quick gas ignition with the risk of damage to property and p...

Страница 4: ...plate Due to the risk of embers falling out a flammable floor must be protected by a hearth plate It must extend 300 mm in front of the stove and 100 mm on each side of the stove or have a 200 mm extension on each side of the opening The hearth plate can consist of natural stone concrete metal plate or glass A painted metal or glass hearth plate is available as an accessory for these models Import...

Страница 5: ...outside that is connected to the connector on the underneath of the stove The amount of air needed for combustion is approx 25m3 h The connector has an external diameter of 67 mm When installing ducts longer than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a ...

Страница 6: ...of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommended chimney length is 3 5 m and suitable cross sectional area is 150 200 cm 140 160 mm in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimney The maximum horizontal flue is 1 m on the condition that the vertical flue length is at...

Страница 7: ...r inlet connector 410 mm G distance to hole in guide plate 288 100 600 890 500 400 300 200 300 400 500 200 Combustible wall Permitted area for combustible material 435 120 8 9 0 810 Combustible wall 238 50 300 590 Fire retardant wall of brick or concrete 365 50 7 9 5 740 Fire retardant wall of brick or concrete Place the stove on the hearth plate and check that the installation distances are not l...

Страница 8: ... so the courses do not end up uneven and crooked Otherwise this can result in abnormally large gaps and uneven lines During assembly check that all the stones stand horizontally and that all parts in a course are of a uniform height Remember to handle the stones with care They scratch easily and the sharp edges are vulnerable to knocks Also take care when the screws are to be tightened so as not t...

Страница 9: ...GB 57 INSTALLATION 5 mm 10 10 VA NA DIU M No 7 C H R O M E Wait to tighten this screw until the next stone is in place Place the profile edge to edge with the stone s side ...

Страница 10: ... 10 VAN ADI UM No 7 C H R O M E 10 10 VAN ADI UM No 7 C H R O M E Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time ...

Страница 11: ...ION Adjustment screws for placement in the guide plate to support the top stones Adjust them so they are at the same height as the top of the side stones Check that the damper can be opened and closed without problem ...

Страница 12: ...BE AB Box 134 SE 285 23 Markaryd Sweden www contura eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu ...

Отзывы: