Contura C 26T Low Скачать руководство пользователя страница 3

GB

51

List of Contents 

Technical details 

52

Supply of combustion air 

53

Connection to chimney 

54

Installation distances 

55

Installation of C26T High 

56

A warm welcome to Contura.

A warm welcome to the Contura family. We hope you 
will get a great deal of pleasure from your new stove. 
As a new owner of a Contura stove, you have secured 
a product with timeless design and long service life. 
Contura also has a combustion process that is both 
environmentally friendly and efficient, for the best heat 
production.

Read through these installation instructions carefully 
before installation. Read how to best light your stove 
in the lighting instructions.

The stove becomes very hot

During operation, certain surfaces of the stove become 
very hot and can cause burn injuries if touched. Also, take 
heed of the strong heat radiated through the door glass. 
Placing flammable material closer than the safe distance 
indicated may cause a fire. Smoulder combustion can cause 
quick gas ignition with the risk of damage to property and 
personal injury. 

NOTE!

WARNING!   

Report the installation of a stove to your 
local authority.

The owner of the house is personally responsible 
for ensuring compliance with the mandatory safety 
requirements and must have the installation approved by 
a qualified inspector. Your local chimney sweep must also 
be informed about the installation, as this will affect the 
routines for regular chimney-sweeping services.

CONTENTS

Содержание C 26T Low

Страница 1: ...Installation instructions C 26T Low www contura eu ...

Страница 2: ...ECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 600 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 09 NOx 82 mg m3 OGC 43 mg m3 PM 22 mg m3 Surface temperatures Approved Cleaning opti...

Страница 3: ...e in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injuries if touched Also take heed of the strong heat radiated through the door glass Placing flammable material closer than the safe distance indicated may cause a fire Smoulder combustion can cause quick gas ignition with the risk of damage to property and p...

Страница 4: ...plate Due to the risk of embers falling out a flammable floor must be protected by a hearth plate It must extend 300 mm in front of the stove and 100 mm on each side of the stove or have a 200 mm extension on each side of the opening The hearth plate can consist of natural stone concrete metal plate or glass A painted metal or glass hearth plate is available as an accessory for these models Import...

Страница 5: ...outside that is connected to the connector on the underneath of the stove The amount of air needed for combustion is approx 25m3 h The connector has an external diameter of 67 mm When installing ducts longer than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a ...

Страница 6: ...of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommended chimney length is 3 5 m and suitable cross sectional area is 150 200 cm 140 160 mm in diameter A flue with sharp bends and horizontal routing reduces the draught in the chimney The maximum horizontal flue is 1 m on the condition that the vertical flue length is at...

Страница 7: ...r inlet connector 410 mm G distance to hole in guide plate 288 100 600 890 500 400 300 200 300 400 500 200 Combustible wall Permitted area for combustible material 435 120 8 9 0 810 Combustible wall 238 50 300 590 Fire retardant wall of brick or concrete 365 50 7 9 5 740 Fire retardant wall of brick or concrete Place the stove on the hearth plate and check that the installation distances are not l...

Страница 8: ... so the courses do not end up uneven and crooked Otherwise this can result in abnormally large gaps and uneven lines During assembly check that all the stones stand horizontally and that all parts in a course are of a uniform height Remember to handle the stones with care They scratch easily and the sharp edges are vulnerable to knocks Also take care when the screws are to be tightened so as not t...

Страница 9: ...GB 57 INSTALLATION 5 mm 10 10 VA NA DIU M No 7 C H R O M E Wait to tighten this screw until the next stone is in place Place the profile edge to edge with the stone s side ...

Страница 10: ... 10 VAN ADI UM No 7 C H R O M E 10 10 VAN ADI UM No 7 C H R O M E Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting for the first time ...

Страница 11: ...ION Adjustment screws for placement in the guide plate to support the top stones Adjust them so they are at the same height as the top of the side stones Check that the damper can be opened and closed without problem ...

Страница 12: ...BE AB Box 134 SE 285 23 Markaryd Sweden www contura eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu ...

Отзывы: