Revision 2.6
WebRelay-Quad™
Users Manual
2.2 Connection
CAUTION: MAKE SURE POWER IS SHUT OFF BEFORE WIRING!
Two removable terminal connectors are provided for simple wiring to WebRelay-Quad™. The
correct wiring procedure is as follows;
1. Make sure power is turned off.
2. Remove terminal connectors from WebRelay-Quad™
and make wiring connections to the
terminals.
3. Reconnect terminal connectors.
4. Apply power.
It is recommended that the load (device to be controlled) not be connected to WebRelay-Quad™
until after WebRelay-Quad™
has been configured and tested. By doing this, wiring and
configuration mistakes will not cause the load device to turn on unexpectedly.
IMPORTANT: MAKE SURE WIRES ARE PROPERLY ATTACHED TO THE TERMINALS!
Xytronix Research & Design, Inc.
page 12
B a d C o n n e c t o r E x a m p l e .
G o o d C o n n e c t o r E x a m p l e .
W i r e s a r e s t r i p p e d t o o f a r b a c k
S t r a n d ( s ) o f w i r e a r e l o o s e
W i r e s a r e s t r i p p e d c o r r e c t
a m o u n t a n d t h e r e a r e n o l o o s e
s t r a n d s t h a t c a n c a u s e s h o r t s