11
13
Remove the UD55 from the Drive; if no other small option module is
required in the Drive, the UD55 can remain permanently fitted.
14
If required, fit a small option module.
15
Replace the terminal cover. The Drive can now be used.
6.2 Transferring parameter-sets between
Drives of different ratings
Warning
Values of certain motor parameters are not scaled correctly
when the current or voltage rating of the destination Drive
differs from that of the source Drive. For safety, refer to
the next instruction.
When transferring a parameter-set between Drives of different current or
voltage rating a
FSH.rng
trip will occur. All parameters will be copied
except those below:
•
2.08
Standard ramp voltage
•
4.05 – 4.07
Current limits
•
4.08
Torque reference
•
4.09
Torque offset
•
5.07
Motor – rated current
•
5.09
Motor – rated voltage
•
5.17
Stator Resistance
•
5.18
Switching frequency
•
5.24
Motor leakage inductance
•
5.33
Thermal model enable
•
6.06
D.C. injection braking current
•
15.07
Regen unit voltage setpoint
These parameters will need to be manually entered into the destination
Drive if the trip occurs.
Note
With software versions before V03.xx.07, no trip will
occur and all parameters will be copied. The above
parameters should be manually entered into the
destination Drive and any other parameters that need to
be set up for the application.