Signal connections
3.9.1
Analog control
Figure 3-6 Power and signal connections for analog control
Make signal connections to terminal block TB1, as follows:
3.9.2
Digital control
Figure 3-7 Power and signal connections for digital control
TB1
Function
1
Field economy contact
Connect to terminal 2 for normal
operation
Disconnect for field economy
2
0V common
3
Field-current amplifier input
Do not connect
4
-15V, 10mA max. output
Use to supply external devices
5
+15V, 10mA max. output
Use to supply external devices
6
Field-current output signal
0 to 10V represents 0 to IF max.
7
Armature-voltage output signal
0 to ±10V represents 0 to ±600V armature
voltage
8
Field-current failure relay
Common contact
9
Contact closed when field current is
normal
10
Contact open when field current is normal