107
Setting Up Parameters
Gearing View
Figure 61:
Gearing View
Gearing is used to fix the motion of the motor to the motion of the master axis signal at a
specified ratio. This is commonly called “electronic line shafting” or “electronic gearing”. To
gear the motor to the master axis, a ratio must be specified as a relationship between follower
distance units and master distance units. The ratio is as follows:
The ratio is defined as the number of follower distance units to move the motor per master
distance unit of travel. The master distance units are configured on the Master Setup screen.
The gear ratio can be positive or negative and is a signed 32-bit parameter. The resolution of
the parameter is determined by the number of decimal places configured for the Master
Velocity Units on the Master Setup screen.
By default, gearing does not use acceleration or deceleration ramps with respect to the master
encoder. This means that once gearing is activated, peak torque is available to try to achieve
the specified gear ratio. Therefore, if the master axis is already in motion when gearing is
activated, the control loop will attempt to accelerate the motor to the programmed ratio within
one update (800µsec < update rate < 1600 µsec). Analogously, when gearing is deactivated,
the motor will use peak torque to bring the motor to a stop without a deceleration ramp.
# of Follower Distance Units
Gear Ratio = -------------------------------------
1 Master Distance Unit
Содержание FM-3
Страница 2: ......
Страница 14: ...xii ...
Страница 16: ...2 FM 3 Programming Module Reference Manual Figure 2 FM 3 Programming Module Features ...
Страница 128: ...114 FM 3 Programming Module Reference Manual ...
Страница 156: ...142 FM 3 Programming Module Reference Manual ...
Страница 196: ...182 FM 3 Programming Module Reference Manual ...
Страница 238: ...224 FM 3 Programming Module Reference Manual ...
Страница 251: ...237 Diagnostics and Troubleshooting Figure 97 Diagnostic Cable DGNE Diagram ...
Страница 262: ...248 FM 3 Programming Module Reference Manual ...
Страница 264: ...250 FM 3 Programming Module Reference Manual AX4 CEN CDRO ...
Страница 265: ...251 Specifications Cable Diagrams ...
Страница 266: ...252 FM 3 Programming Module Reference Manual SNCE XXX Cable SNCDD 001 5 Cable ...
Страница 267: ...253 Specifications SNCO 003 Cable SNCI 003 Cable ...
Страница 268: ...254 FM 3 Programming Module Reference Manual SNCLI 003 Cable ...
Страница 271: ...257 Specifications CDRO XXX Cable 8 9 24 23 38 37 11 12 34 16 14 15 29 4 19 26 40 18 17 31 33 43 44 41 27 ...
Страница 272: ...258 FM 3 Programming Module Reference Manual TIA XXX Cable DDS XXX Cable ...
Страница 274: ...260 FM 3 Programming Module Reference Manual CMDS XXX Cable CMMS XXX Cable ...
Страница 275: ...261 Specifications CFCS XXX Cable ...
Страница 276: ...262 FM 3 Programming Module Reference Manual CFCO XXX Cable ...
Страница 277: ...263 Specifications CFOS XXX Cable ...
Страница 278: ...264 FM 3 Programming Module Reference Manual ...
Страница 286: ...272 FM 3 Programming Module Reference Manual ...
Страница 290: ...276 FM 3 Programming Module Reference Manual ...
Страница 291: ......