3.2
Connections
Figure 3-2 DeviceNet Module connections
Digistart CS
Digistart IS
08647.
A
1
2
3
V -
CA
N_
L
S
h
ie
ld
CA
N_
H
V +
08648.
A
1
2
3
V -
CA
N_
L
S
h
ie
ld
CA
N_
H
V +
Digistart CS
Digistart IS (Remote mode)
DeviceNet Module
DI2, +24V: Stop
Standard connection onto DeviceNet network
DI3, +24V: Reset
DeviceNet Module
Standard connection onto DeviceNet network
For the DeviceNet Module to accept serial commands, a link must be fitted across terminals CSL-DI2 on Digistart CS starters.
Input links are required across terminals DI2, +24V and DI3, +24V if the Digistart IS soft starter is being operated in Remote mode. In
Local mode, links are not required.
NOTE
Digistart IS Pr
3O
Comms in Remote
selects whether the soft starter will accept Start, Stop or Reset commands from the
Serial Network Master while in Remote mode. See the Digistart IS User Manual for parameter details.
3.3
Module and network LEDs
The Module LED indicates the condition of the power supply and module operation.
The Network LED indicates status of the communication link between the DeviceNet Module and the network Master.
Figure 3-3 Feedback LEDs
1
2
LED
State
Description
(Module)
Off
Network power off
Green
Normal operation
Red
Unrecoverable fault
Red/Green flashing
Self Test mode
(Network)
Off
Duplicate MAC ID test has not been completed
Green flashing
Online but no connection with Master
Green
Online and allocated to a Master
Red flashing
One or more timed out I/O connections
Red
Failed communication between module and Master
Red/Green flashing
Communication faulted and received an Identity communication
faulted request
NOTE
When a communications failure occurs, the soft starter may trip if the Communication Timeout parameter for the network is
set greater than zero. When communication is restored, the soft starter must be reset.
Содержание 0477-0008-01
Страница 20: ...20 Guide de mise en service Module DeviceNet www controltechniques com Indice 1 ...
Страница 30: ...30 DeviceNet Modul Betriebsanleitung www controltechniques com Ausgabe 1 ...
Страница 40: ...40 Guida dell utente del modulo DeviceNet www controltechniques com Versione numero 1 ...
Страница 50: ...50 Guía del Usuario Módulo DeviceNet www controltechniques com Versión 1 ...
Страница 60: ......