background image

 

17 

 

 

  For current status, press 1. 

 

 

  For remote switch status, press 2.   

 

 

  To enter the Program Menu, press 3. 

 
 

 

Current Status:  Provides the current status of the various sensors. 

 

 

The current temperature is XX degrees, the power is on (or off), the 
battery is at X.XX volts and the auxiliary alarm input is currently  

 

 

(in/not in) alarm mode. 

 
 

 

Remote Switch Status:  This is where you can easily change the position 

of the remote switch status.  This can be used to switch between one 
thermostat set at a lower temperature to another thermostat set at a 
higher temperature, allowing you essentially warm up a space before 
you arrive.  It can also be used to turn on or off a remote device by 
telephone.  Use of this feature is detailed in Appendix B on page 39. 

 
 

 

Program Menu:  It is recommended you listen to all the menu options 

once before programming to become familiar with the program menu.  
At the end of the menu, it will pause and then start playing from the 
beginning again. 

 

4.

 

IMPORTANT: After programming is completed, flip the front 
ON/STANDBY switch to the ON position for normal operation of your 
FreezeAlarm.   

 

IMPORTANT WARNING!  After Programming, you must 
return the front toggle switch to the ON position or the 
FreezeAlarm will not call you if an alarm condition occurs and 
you will be unable to call into your FreezeAlarm remotely! 

 

CRITICAL!  TEST YOUR FREEZEALARM to make sure it 
calls your call-to telephone numbers during an alarm.  See the 
Test Procedure detailed on page 18. 

 
2.4  Programming Your FreezeAlarm Remotely: 
 

By calling into your FreezeAlarm from a remote phone or cell phone 
1.

 

Make sure all the connections have been made according to section 1.5 on 
page 8.  You will not need to plug a phone into the “PROGRAM PHONE” 
jack on the front of the FreezeAlarm to program the FreezeAlarm remotely. 

2.

 

Make sure the toggle switch on the front of the FreezeAlarm is in the ON 
position. 

3.

 

From an outside phone or a mobile/cell phone, call the telephone number of 
your monitored location.  The FreezeAlarm will answer after five rings have 
been heard by the FreezeAlarm.  If you have an answering machine or voice 
mail at the monitored location, you may need to place two or more calls to 

 

18 

the monitored location to circumvent the answering machine or voice mail.  
For more details on this topic, see the section about Answering Machines 
and Voice Mail on page 21. 

4.

 

When the FreezeAlarm answers, you will hear the following: 

 

 

Hello, this is your automated monitoring system (or a custom greeting 
message if recorded earlier).  The current temperature is XX degrees, the 
power is on 
(or off), and the battery is at X.XX volts. 

 
 

 

If no alarm conditions are present at the current time, you will then hear: 

 
 

 

There are no alarm conditions occurring at this time.  To access the main 
menu, enter your four digit security code followed by the pound (#) key.
 

 
 

 

If alarm conditions do exist when you call into your FreezeAlarm, the 
FreezeAlarm will play any alarm conditions present at that time instead of 
the above message.  See the section What Happens During An Alarm on 
page 22 for more details on what to do if this message is playing.  You can 
still continue to remotely program the unit even if alarm conditions are 
present. 

5.

 

Enter your four digit security code followed by # on your telephone key pad.  
If the security code is correct, the main menu will play.  If the security code 
is incorrect, you will be given one more chance and then the FreezeAlarm 
will say Incorrect Security Code, good-bye and then hang up. 

6.

 

From the Main Menu, select menu option 3 to enter the Program Menu.  
From the program menu, you can review or program your call-to telephone 
numbers, security code, temperature alarm setpoints, and other options.  
There are six programming options in the Programming Menu.  Each Menu 
Option is discussed in detail in section 2.2.   

7.

 

IMPORTANT: Flip the front ON/STANDBY switch to the ON position for 
normal operation of your FreezeAlarm. 

 

IMPORTANT WARNING!  After Programming, you must 
return the front toggle switch to the ON position or the 
FreezeAlarm will not call you if an alarm condition occurs and 
you will be unable to call into your FreezeAlarm remotely! 

 

CRITICAL!  TEST YOUR FREEZEALARM to make sure it 
calls your call-to telephone numbers during an alarm.  See the 
Test Procedure detailed below. 

 
2.5 Testing Your FreezeAlarm
 
 

It is CRITICAL that you test your FreezeAlarm to ensure you have programmed 
all the telephone numbers correctly and to make sure the FreezeAlarm is working 
properly with your telephone line.  Before you start the test, make sure the front 
toggle switch is in the ON position. 

Содержание Deluxe FreezeAlarm FA-D2

Страница 1: ...eed to monitor two different homes Cabin and Vacation Property Owners can monitor their home and pre heat it by phone Monitor a refrigerator or freezer from getting too warm since the Deluxe model has...

Страница 2: ...Program Menu Call In Menu and Alarm Menu Flow Charts 35 B Remote Switch Wiring Diagrams Installation Notes 39 4 1 0 INITIAL SET UP BEFORE YOU PROCEED Read the Following Warranty Statement Please read...

Страница 3: ...nit is in the STANDBY mode During normal operation with no alarms present this light will not be on This light will remain ON and not flash if the unit is in ALARM mode meaning one of the alarm condit...

Страница 4: ...lanation of each dip switch setting UP means the switch should be pointing towards the top of the FreezeAlarm case and DOWN means the switch should be pointed towards the bottom of the case All the sw...

Страница 5: ...y Alarm Input is either closed or opened depending upon the setup it will trigger the FreezeAlarm to begin calling your preprogrammed telephone numbers and play a special message you can record for wh...

Страница 6: ...sage The auxiliary alarm input is in alarm mode Auxiliary Alarm Input Setting Normally Open 12 IMPORTANT WARNING After Programming you must return the front toggle switch to the ON position or the Fre...

Страница 7: ...plug a phone into the front of the FreezeAlarm go to menu option 3 in the programming menu and review or change the security code at that time If you are receiving alarm calls from your FreezeAlarm th...

Страница 8: ...e but decide you would rather have the factory default message instead you can reinstate the factory default alarm or greeting message 1 Select the menu option 6 to record messages 2 Press 1 To Review...

Страница 9: ...ed location to circumvent the answering machine or voice mail For more details on this topic see the section about Answering Machines and Voice Mail on page 21 4 When the FreezeAlarm answers you will...

Страница 10: ...ient rings to allow you to get to the call well before the FreezeAlarm answers NOTE If you leave your FreezeAlarm in the STANDBY mode the FreezeAlarm will not call you if there is an alarm and you wil...

Страница 11: ...your FreezeAlarm is set to answer on five rings 22 3 If you wish to call your FreezeAlarm place two calls to your monitored location a On the first call let the phone ring two or three times and then...

Страница 12: ...eset during the day and call you again at night at 2am of course 3 5 How to Cancel the Alarm Call Out and reset your FreezeAlarm Two things need to happen to reset the FreezeAlarm The alarm call out m...

Страница 13: ...in menu functions or hang up If the Alarm Call Out Has Been Canceled By Someone Else Since the FreezeAlarm can call multiple phone numbers there is a chance that a person at one of the other call to l...

Страница 14: ...e the battery drops to about 6 0 volts the FreezeAlarm can no longer operate 28 If you wish to have a longer battery option Control Products offers a battery holder that holds 6 D cell batteries in se...

Страница 15: ...dial into the FreezeAlarm try a different phone or even a cell phone 3 The FreezeAlarm is not answering Either the phone lines are down or the power is out and the battery has died preventing the Free...

Страница 16: ...ngly encourage you to fully test this Product in its actual application This should include a full test involving the Product actually dialing to its designated locations and someone verifying the pro...

Страница 17: ...ction to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information 34 If your home has specially wi...

Страница 18: ...currently set as a normally open closed contact To change press 0 or press 9 to return to the main menu Pressing zero will play back the same menu but with the selection changed 0 7 Aux Alarm Setting...

Страница 19: ...ty code Enter your four digit security code followed by the pound key Incorrect security code good bye The alarm callout is now canceled To return to the main menu press 1 otherwise hang up You are no...

Страница 20: ...do not feel comfortable doing this installation yourself contact your local heating or electrical contractor WARNING Improper installation could result in hazardous conditions and damage to the Freeze...

Отзывы: