a)
Missing connectors in SIU aircraft
The SIU serial data is connected from the SIU to the MFD by cable ANMD977-22 (refer to
Cirrus Wiring Manual chapter 77-00-01) and in SR22s with serial numbers 1087 and
above, and SR20s with serial numbers 1456 and above, this cable incorporates a pair of
connectors labelled J719/P719 which provides a convenient place to insert the adapter
harness p/n 4370-03. Aircraft with serial numbers below those ranges may not have
J719/P719 fitted and installation of BlueMAX will be facilitated if those connectors are
installed in accordance with the Cirrus Wiring Manual chapter 77-00-01. The necessary
connectors can be ordered from Control-J as part number 4370-9869.
Figure 1: Analog engine instruments
6.3
Verify primary engine data on PFD for DAU aircraft
DAU equipped aircraft display primary engine data on the PFD, but this requires that the
software version installed on the PFD supports this display. To verify this, power up the
aircraft and inspect the lower right area of the PFD. There should be a data block with
primary engine data as shown in Figure 2: Primary engine data on PFD
.
If this data is
absent, the PFD software must be upgraded before installing BlueMAX.
The applicable aircraft models, serial numbers and configurations are summarised in
Table 3: Engine monitor types.