a)

 

Missing connectors in SIU aircraft 

The SIU serial data is connected from the SIU to the MFD by cable ANMD977-22 (refer to 
Cirrus Wiring Manual chapter 77-00-01) and in SR22s with serial numbers 1087 and 
above, and SR20s with serial numbers 1456 and above, this cable incorporates a pair of 
connectors labelled J719/P719 which provides a convenient place to insert the adapter 
harness p/n 4370-03. Aircraft with serial numbers below those ranges may not have 
J719/P719 fitted and installation of BlueMAX  will be facilitated if those connectors are 
installed in accordance with the Cirrus Wiring Manual chapter 77-00-01. The necessary 
connectors can be ordered from Control-J as part number 4370-9869. 

 

 

Figure 1: Analog engine instruments 

6.3

 

Verify primary engine data on PFD for DAU aircraft 

DAU equipped aircraft display primary engine data on the PFD, but this requires that the 
software version installed on the PFD supports this display. To verify this, power up the 
aircraft and inspect the lower right area of the PFD. There should be a data block with 
primary engine data as shown in Figure 2: Primary engine data on PFD

If this data is 

absent, the PFD software must be upgraded before installing BlueMAX. 

The applicable aircraft models, serial numbers and configurations are summarised in 
Table 3: Engine monitor types. 

Содержание BlueMAX

Страница 1: ...LUEMAX INSTALLATION INSTRUCTIONS i BlueMAX Bluetooth Adapter Installation Instructions Document no 2456 05 Date 2017 03 20 Revision 3 Approved Control J Pty Ltd 100 Hursley Rd Redbank NSW 2446 Austral...

Страница 2: ...ii BLUEMAX INSTALLATION INSTRUCTIONS Document number 2456 05 Revision 3 Copyright 2017 Control J Pty Ltd...

Страница 3: ...ION INSTRUCTIONS iii Document number 2456 05 Revision 3 iii Revision History Date Revision Document Changes 2017 02 17 1 Initial Draft 2017 02 22 2 Revised document list 2017 02 22 3 Placard CB Flight...

Страница 4: ...in SIU aircraft 9 6 3 Verify primary engine data on PFD for DAU aircraft 9 7 Installation with MFD permanently removed 10 8 Parts required 11 9 Tools required 11 9 1 Probing connector P1426B 11 10 In...

Страница 5: ...List of Tables Table 1 BlueMAX Technical specifications 7 Table 2 Referenced Documents 8 Table 3 Engine monitor types 10 Table 4 BlueMAX part numbers 11 List of Figures Figure 1 Analog engine instrum...

Страница 6: ...e in Cirrus SR22 and SR20 aircraft and these instructions relate specifically to those models 2 Definitions The following abbreviations and acronyms are used in this document BLE Bluetooth Low Energy...

Страница 7: ...hould be 20AWG which is rated to 7 5A per AC 43 13 1B 6 Preparation for installation 6 1 Aircraft identification Cirrus aircraft fitted with Perspective avionics are not eligible for BlueMAX installat...

Страница 8: ...IRPLANE WIRING MANUAL FOR THE CIRRUS SR20 12129 001 C5 2016 01 01 AIRPLANE MAINTENANCE MANUAL FOR THE CIRRUS SR20 12137 001 B7 2016 01 01 AIRPLANE MAINTENANCE MANUAL FOR THE CIRRUS SR22 AND SR22T 1377...

Страница 9: ...if those connectors are installed in accordance with the Cirrus Wiring Manual chapter 77 00 01 The necessary connectors can be ordered from Control J as part number 4370 9869 Figure 1 Analog engine i...

Страница 10: ...gine data displayed on PFD G1 G2 SR20 1005 1581 SIU SIU must be fitted G2 SR20 1582 1877 1879 1885 DAU G2 Verify primary engine data displayed on PFD G3 SR20 with Avidyne Avionics 1878 1886 subsequent...

Страница 11: ...ere may be cable ties wire splices and other common electrical parts required these are not included in the kit Installation type BlueMAX module Adapter Harness Connectors Kit SIU 4370 2730 4370 5146...

Страница 12: ...D977 22 running from the SIU to the MFD and install P719 and J719 in accordance with the Cirrus Wiring Manual c Disconnect P719 and J719 from each other and re connect to the SIU harness p n 4370 5146...

Страница 13: ...ing structure or wire bundles using cable ties j Replace MFD IAW the Cirrus AMM 10 4 G3 Aircraft a Remove MFD to gain access behind the instrument panel b Locate P1047 and J1047 These will be directly...

Страница 14: ...ons for continued airworthiness No routine maintenance or inspection of the BlueMAX module is required Correct display of primary and supplementary engine data should be monitored during normal operat...

Отзывы: