The 8-Port Ethernet Switch specifications include:
Power
110V-277VAc, 50/60 Hz
Operating Temperature
32˚F to 104˚F (0˚C to 40˚C)
Power Consumption
2W
Communications
10/100 Ethernet
Connectors
Three (3) Screw Terminals (Line,
Neutral, Ground), one (1) 26AWG
to 12AWG (.12 - 4mm
2
) per ter-
minal
Eight (8) RJ-45 Ethernet
Humidity
5% - 95%
Non-condensing
Storage
-4˚ F - 158˚ F
(-20˚ C - 70˚ C)
Dimensions (HxWxD)
8.5” x 4.3” x 2.3” (215 mm x 109
mm x 57 mm)
DIN Module Width
12M
Weight
2.3 lbs. (1.04 kg)
Shipping Weight
2.8 lbs. (1.27 kg)
Front View
Figure 1. Front View
1 Power
LED
2 Link/Activity
LEDs
3 Reset
button
4
Ethernet RJ-45 Connectors
5
Line Voltage Connector
Pre-Installation Instructions
Before You Install in a Control4 Panel
1
Use Composer Pro to add the 8-Port Ethernet Switch to a project, define its
location in a panel, and print the panel report. See the
Composer Pro User
Guide
for details.
2
Install the panel following the instructions in the
5-Slot and 2-Slot Panel
Installation Guide
.
3
Install and wire the Terminal Block for the 8-Port Ethernet Switch following
the instructions in the
Terminal Block Installation Guide
and in the location
defined by the Composer Pro panel reports.
Before You Install in a Third-Party DIN Rail Panel
1
Install the third-party panel according to the third-party instructions.
Supported Model
đŏ
C4-DIN-8ESW-E 8-Port Ethernet Switch (DIN Rail)
Introduction
The Control4® 8-Port Ethernet Switch is part of the Control4 Panelized Lighting
System. It installs in the Control4 5-Slot or 2-Slot Panel or in any standard DIN rail
panel with 35mm rails. The Ethernet Switch is a standard 8-port 10/100 switch
that allows a single Ethernet CAT5e cable to be pulled into the panel, and then
distributed to up to seven (7) other Control4 panelized lighting devices in the
panel.
Box Contents
đŏ
8-Port Ethernet Switch
đŏ
Warranty Card
đŏ ĉġ+.0ŏ0$!.*!0ŏ3%0$ŏ */0((0%+*ŏ1% !
(this document)
đŏ
8-Port Ethernet Switch Wiring Guide
Warnings and Considerations
WARNING!
Improper use or installation can cause SERIOUS INJURY,
DEATH or LOSS/DAMAGE OF PROPERTY.
ATTENTION!
Une mauvaise utilisation ou installation peut entraîner des
blessures graves, décès ou perte / dommages à la propriété.
WARNING!
This device must be protected by a circuit breaker (20A max).
ATTENTION!
Cet appareil doit étre protègè par un disjoncteur (20A max.)
WARNING!
Ensure that all circuit breakers feeding into the panel are OFF
before installing or servicing the devices.
ATTENTION!
Assurez-vous que tous les disjoncteurs d’alimentation dans
le panneau sont éteints avant d’installer ou de réparer l’appareil.
IMPORTANT!
Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See “Troubleshooting.”
IMPORTANT!
Changes or modifications not expressly approved by
Control4 could void the user’s authority to operate the equipment.
IMPORTANT!
The Ethernet Switch should be installed by a licensed
electrician in accordance with all national and local electrical codes.
Requirements and Specifications
Prior to installing this product, ensure that the Control4 5-Slot or 2-Slot Panel or
that the cabinet to house the switch has been installed.
8-Port
Ethernet Switch
Installation Guide
1
2
4
3
5