3.4 Air Requirements
The following table shows compressed air consumption (m
3
/min) at 8 bar working pressure
when nozzles are new and when they are considered worn (ca. 1,5mm larger than original).
Tab. 3.4.1 Nozzle, Leg Set And Compressor Recommendations
Nozzle
Leg set
Compressor capacity
new nozzle, (m
3
/min)
Compressor capacity
worn nozzle, (m
3
/min)
PBN-5.0
Short set: 12“ (300 mm) – 20“
(500 mm)
6
8
PBN-6.5
Short set: 12“ (300 mm) – 20“
(500 mm)
8
12
PBN-8.0
Long set: 24“ (600 mm) – 36“
(900 mm)
12
16
PBN-9.5
Long set: 24“ (600 mm) – 36“
(900 mm)
16
20
The pneumatic drive motor requires additional ca. 1,5 m
3
/min of dry clean air for proper
operation.