11
CONTRACOR
®
BlastRazor Z-25RC/BlastRazor Z-50RC Art. 10400301 /10400402
Problem
Cause
Solution
Air does not come out of
the vent in the RC handle
body.
Twinline hose is clogged or
pinched.
Disconnect the Twinline hose and ensure that
it is not clogged.
Control valve does not
open.
Safety drain valve is still
open.
Close the safety drain valve.
Air feed to abrasive
blasting machine is not
sufficient.
Dismantle the control valve, all
parts should rotate freely.
RC control valve does
not close.
RC handle channels are
clogged.
Remove the key and clean it.
Incorrect connection of
TWINLINE hose.
Check connections and change them if they
are incorrect.
Control valve failure.
Disassemble the valve and ensure that it
functions properly.