PIZZA PREP TEMP ADJUSTMENT - COLDWALL RAIL
If an adjustment is necessary to maintain the coldwall rail temperature, a pressure
control is located behind the front grill which controls the compressor operation and
the temperature range of the rail. The factory recommended settings for this low
pressure control are the following:
CUT IN = 45#
DIFFERENTIAL = 20#
Before making any adjustments to the pressure control out of the factory design
temperature range, please consult factory or a qualified refrigeration mechanic.
UNDERCOUNTER REFRIGERATOR SYSTEM AND ADJUSTMENT
All self-contained undercounter refrigerators are designed and factory set to
maintain an average cabinet temperature of 38°F. The temperature control is
accessible inside of the cabinet product compartment, on the right back wall
next to the evaporator coil (see figure 7 for thermostat location). If an adjustment
is necessary to maintain the above temperature range
only
, place a screwdriver
into the thermostat slot and turn clockwise for a colder cabinet temperature or
counterclockwise for a warmer cabinet temperature. Further adjustments out of
the factory design temperature range must be made by a qualified refrigeration
mechanic only.
Important Note:
All refrigerators are designed with an automatic, “off-cycle”
defrost system which means that defrosting occurs automatically when the
compressor is not operating during an off-cycle.
Do not
set the thermostat too
cold where the cabinet temperature will fall below 35°F because the evaporator
will become blocked by ice since the compressor off-cycle will be considerably
shortened. This will result in loss of food stored within the cabinet and require
service to defrost the evaporator and re-adjust the thermostat.
UNDERCOUNTER FREEZER SYSTEM AND ADJUSTMENT
All self-contained undercounter freezers are designed and factory set to maintain
an average cabinet temperature of 0°F. All freezers are designed for the purpose
of holding pre-frozen food and although they are capable of freezing small quantities
of fresh food, they are not to be used as fast or blast freezers.
Do not
attempt to
freeze bulk quantities of fresh foods. The temperature control is accessible inside
of the cabinet product compartment, on the right back wall next to the evaporator
coil (see figure 7 for thermostat location). If an adjustment is necessary to maintain
the above temperature range only, place a screwdriver into the thermostat slot and
turn clockwise for a colder cabinet temperature or counterclockwise for a warmer
cabinet temperature. Further adjustments out of the factory design temperature
range must be made by a qualified refrigeration mechanic only.
16