703 S. Cleveland Massillon Road, Fairlawn, OH 44333 I 800.234.4632 I www.contitech.us
Crimper Specifications and Initial Set Up
Specifications:
Max Head Opening W/O Dies ---------------------------------------------------------------- 284 MM (9.75 IN)
Master Die Inside Diameter -------------------------------------------------------------------- 160 MM (6.3 IN)
Maximum Opening ---------------------------------------------------- Die Closed Di 102 MM (4 IN)
Crimper Size ------------------------------------------------------------ 48 IN Wide X 44 IN Deep X 61 IN High
Weight --------------------------------------------------------------------------------------------- 1840 LB. (835 KG)
Electrical Requirements ----------------------------------------------------------- 230 Volt 3 Phase (Standard)
----------------------------------------------------------- 480 Volt 3 Phase (Optional)
---------------------------------------------- 5 HP 230 Volt Single Phase (Optional)
Motor ---------------------------------------------------------------------------------------- 7.5 HP (1 Stage Pump)
Reservoir Capacity ------------------------------------------------------------------------------------------ 8 US GAL
Oil Type ----------------------------------------------------------------------------------------- ISO 46 Hydraulic Oil
Adapter Dies -------------------------------------------------------------------------------------160 MM to 99 MM
Hose Capacity ----------------------------------------------------------------------------------------- 2 Inch 4 Spiral
--------------------------------------------------------------------------------------- 4 Inch Industrial
Initial Crimper Set Up
•
Check reservoir oil level with sight glass on the front of the power unit.
•
Check electrical circuit to be certain that it matches the crimper requirements as shown on
the tag attached to the crimper cord.
•
Make certain that motor rotates in the direction of the arrow shown on the motor housing.
•
If motor rotation is incorrect reverse any two hot wires in the crimper plug. (For 3 phase
circuits)
•
Also see additional information on the initial set up and maintenance page.
Содержание PC440
Страница 1: ...703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...
Страница 16: ...Exploded Parts View 703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...
Страница 17: ...Exploded Parts View 703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...
Страница 18: ...Exploded Parts View 703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...
Страница 19: ...Exploded Parts View 703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...
Страница 20: ...Exploded Parts View 703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...
Страница 21: ...Exploded Parts View 703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...
Страница 22: ...Exploded Parts View 703 S Cleveland Massillon Road Fairlawn OH 44333 I 800 234 4632 I www contitech us ...