ThE TWo INlETS To ThE DRAIN TRAp ARE FoR VENT pIpE AND CoNDENSATE
CollECTIoN. ThE VENT pIpE INlET IS SmAllER ThAN ThE CoNDENSATE
CollECTIoN INlET. ENSuRE ThAT ThE DRAIN hoSES ARE pRopERly CuT To ThE
REquIRED lENgTh CoNNECTED AND SECuRED.
CAuTIoN
!
!
11 .4 DRaIn hose InsTallaTIon
1. Connect one end of the 5/8” tubing (in parts bag) to the most direct drain outlet on the front manifold cover,
and the other end to the larger elbow on the condensate trap assembly. Cut excess tubing if necessary
and hold in place with the supplied plastic hose clamps (in parts bag).
2. Connect one end of the 1/2” tubing, using the reducing coupling (in parts bag), to the lower drain outlet
on the exhauster coupling, and the other end to the smaller elbow on the condensate trap assembly. Cut
excess tubing if necessary.
Condensate from the outlet of the drain trap assembly must be conveyed to a floor drain, sump pit, or, if these
are unavailable, to a condensate pump. If using a condensate pump, be sure that it is approved for furnace
condensate.
11.4.1
DRaIn pIpInG
NOTE
All condensate drain tubing must slope towards the condensate trap, ensuring that the drain
hoses do not create traps prior to the condensate trap assembly.
Do NoT DRAIN ThE CoNDENSATE ouTDooRS. Do NoT RuN ThE CoNDENSATE lINE
ThRough AREAS WhERE FREEZINg mIghT oCCuR. FREEZINg oF CoNDENSATE CAN
RESulT IN ERRATIC FuRNACE opERATIoN AND IN pRopERTy DAmAgE.
CAuTIoN
!
!
IMPORTANT:
ThE CoNDENSATE DRAIN TRAp ASSEmbly ShoulD bE Full oF WATER (pRImED)
bEFoRE STARTINg ThE FuRNACE. To FIll ThE CoNDENSATE DRAIN TRAp ASSEmbly,
TEmpoRARIly REmoVE ThE VENT DRAIN hoSE FRom ThE ExhAuSTER ASSEmbly
ElboW/DRAIN FITTINg, AND pouR AppRoxImATEly oNE Cup oF WATER DoWN ThE
hoSE. WATER WIll bEgIN RuNNINg ouT ThE CoNDENSATE DRAIN TRAp ouTlET
WhEN IT IS Full. REFASTEN ThE VENT DRAIN hoSE To ThE ExhAuSTER ASSEmbly
ElboW/DRAIN FITTINg.
ThE CoNDENSATE DRAINAgE CoNFIguRATIoN REquIRES A VENT. IT TAkES lESS
ThAN A oNE INCh RISE ANyWhERE AloNg ThE hoRIZoNTAl RouTE oF ThE DRAIN
TubE To CREATE A VApoR loCk, WhICh WIll pREVENT CoNDENSATE FRom
DRAININg AWAy FREEly, AND RESulT IN ERRATIC FuRNACE opERATIoN.
A typical configuration would be to cement the side branch of a ½” CpVC tee to the drain trap assembly
outlet, with the end branches oriented vertically. (Figure 27)
A 1” piece of ½” CpVC pipe cemented to the upper end branch will serve as a vent, which will prevent the
creation of a vapor lock, and serve as an overflow in the event that the drain line becomes blocked. A similarly
sized piece of pipe cemented to the lower end branch will permit connection to the condensate outlet with
⅝” id / ⅞” oD flexible tubing, or the condensate may be piped entirely in CpVC to the floor drain/sump/
condensate pump.