REQUIRED COMPONENTS:
• CHMF150/200 Hybrid Furnace
• HMFK-BMP50-1 Blower Box Module
• HMFK-SOLID or HMFK-GLASS Door Kit
STEPS:
Completely assemble CHMF150/200 in required left or right hand "RA" con
fi
guration as required.
STEP #1 - #4
Follow Steps 1 to 4 from SECTION 5.1 - HYBRID
CHMF150/200 AS A "ADD ON" TO EXISTING
FURNACE.
STEP #5
○
Locate and level the CHMF150/200 while main-
taining a minimum 1.25" (32mm) clearance space
between the bottom of the furnace and
fl
oor.
○
Use levelling the legs to compensate for uneven
fl
oor and snug lock nuts up to the furnace base to
prevent movement through vibration.
○
Remove the contents of the blower module kit
and compare with the contents list on the "Manu-
al" addendum, accompanying the Blower Module.
○
Remove the shipping bracket from the blower.
STEP #6
○
Place the blower box module with the blower
outlet side facing the rectangular opening on the
side panel.
○
Adjust the levelling legs on the blower box mod-
ule so that the module is level and clearance hole
on the mounting
fl
anges align with pilot holes on
side of the furnace panel.
STEP #7
○
Lift the blower outlet side of blower box so mount-
ing
fl
ange on the bottom of blower box clears the
retaining bracket on the lower edge of the furnace
side.
○
Slide the blower box in so the lower mounting
fl
ange of the blower box is contained between the
fl
ange of the retaining bracket and the furnace
side.
○
Fasten the sides and top mounting
fl
anges of the
blower box using wildrill 1/4" hex head screws.
2
1
3
4
LEVEL LEG
LOCK NUT
RETAINING FLANGE
5.2 HYBRID CHMF150/200 AS A “STAND ALONE” WOOD FURNACE
H3.41
THE INSTALLATION OF THE WOOD FURNACE / COMBINATION WOOD FURNACE MUST BE DONE IN
ACCORDANCE WITH RULES OF AUTHORITIES HAVING JURISDICTION AND THE CAN / CSA B365-01
(R2006) STANDARD FOR SOLID FUEL BURNING APPLIANCES AND EQUIPMENT.
ITEM
DESCRIPTION
HMF150/200 HYBRID FURNACE
1
1
HMFK-BMP50 BLOWER BOX MODULE
1/4" HEX HEAD WILDRIL SCREW
HMFK-SOLID OR HMFK-GLASS DOOR KIT
1
11
1
2
3
4
QTY
W415-1506 / A / 12.04.15
23
EN