background image

37

W415-1540 / 08.04.15

EN

Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of 
the small logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed 
edges of the 

fi

 bre hairs will glow. 

The ember material will only glow when exposed to direct fl ame; 

however, care should be taken to not block the burner ports. 

Blocked burner ports can cause an incorrect 

fl

 ame pattern, carbon deposits and delayed ignition. 

PHAZER

TM

 

logs glow when exposed to direct 

fl

 ame. Use only certi

fi

 ed "glowing embers" and 

PHAZER

TM

 logs available 

from your authorized dealer / distributor. 

6.5 GLOWING 

EMBERS

6.6 LOGO 

PLACEMENT

97.1A

Remove the backing of the logo supplied and place on the glass viewing door, 
as indicated.

½"

(12.7mm)

 

LOGO

½"

(12.7mm)

 

4

5

E.

 

Place the end of log #5 on the left end of

 

log #1 and on the pin of log #2. 

6

E.

 

Place log #6 along the back edge of the grate 
wrapping around the 3rd grate post. Ensure 
logs do not cover any ports.  

Содержание CX70NT

Страница 1: ...nt Installation and service must be performed by a qualified installer service agency or the supplier If the information in these instructions are not followed exactly a fire or explosion may result c...

Страница 2: ...S 30 5 2 1 ALCOVE CLEARANCE TO COMBUSTIBLES ENCLOSURE 31 5 3 NON COMBUSTIBLE FACING MATERIAL 32 5 4 MINIMUM COMBUSTIBLE MANTEL CLEARANCES 33 5 5 NAILING TAB INSTALLATION 33 6 0 FINISHING 34 6 3 SAFETY...

Страница 3: ...CLEARANCE TO COMBUSTIBLE ENCLOSURES for non combustible materials such as tile marble granite etc IMPORTANT Extra support may be required See the section MINIMUM ENCLOSURE CLEARANCES for drywall or ot...

Страница 4: ...no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this appliance if any part has...

Страница 5: ...5 W415 1540 08 04 15 EN 2 1 CX70 DIMENSIONS 33 1 8 841mm CX70 ILLUSTRATED 18 1 2 470mm 7 3 16 182mm 1 15 16 50mm GAS INLET 5 127mm 11 13 16 299mm 8 203mm 35 890mm 11 5 16 288mm 33 1 8 841mm...

Страница 6: ...uld choose a location where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material othe...

Страница 7: ...ng plate This appliance is not convertible for use with other gases unless a certified kit is used When the appliance is installed at elevations above 4 500 ft 1371m and in the absence of specific rec...

Страница 8: ...MINIMUM AND MAXIMUM VENT LENGTHS REFERER AU MANUEL D INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS D EVACUATION MINIMALE ET MAXIMALE WOLF STEEL LTD 24 NAPOLEON ROAD BARRIE ON L4M 0G8 CANADA UN COMBU...

Страница 9: ...itial installation NOTE This appliance must be installed with a continuous connection of exhaust and air intake vent pipes Utilizing alternate constructions such as a chimney as part of the vent syste...

Страница 10: ...in conjunction with the various terminations use either the 5 foot 1 5m vent kit GD420 or the 10 foot 3 1m vent kit GD430 For optimum flame appearance and appliance performance keep the vent length an...

Страница 11: ...VENT INSTALLATION 16 406MM MINIMUM 40 FT 12M MAXIMUM 3 FT 1M MINIMUM TOP VENT 33 1 8 841MM THE FIRST TWO FEET OF OUTER 8 178MM DIAMETER VENT PIPE FROM THE APPLIANCE MUST BE WRAPPED IN THE 1 25MM THIC...

Страница 12: ...rade The periscope must be installed so that when final grading is completed the bottom air slot is located a minimum 12 305m above grade The maximum allowable vent length is 10 3m for a fireplace and...

Страница 13: ...6mm 16 406mm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0 9m 3 0 9m See...

Страница 14: ...eet 10 7m 4 2 times the vertical rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 6 DEFINITIONS 14 1 For the following symbols u...

Страница 15: ...90 03 270 90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4 FT 1 6m 9 9 FT 3m HT VT 9 9 FT 3m 11 FT 3 4m 20 9 FT 6 4m Formula 1 HT VT 9 9 FT 3m 11 FT 3 4m Formula 2 HT VT 40 FT 12 2m 20 9 FT 6 4m 40 FT 12 2m Si...

Страница 16: ...m Formula 2 HT VT 24 75 FT 7 5m 16 7 FT 5 1m 24 75 FT 7 5m Since both formulas are met this vent configuration is acceptable The shaded area within the lines represents acceptable values for HT and VT...

Страница 17: ...FT 1 5m V2 6 FT 1 8m V3 10 FT 3 1m VT V1 V2 V3 5FT 1 5m 6FT 1 8m 10FT 3 1m 21FT 6 4m H1 8 FT 2 4m H2 2 5 FT 0 8m HR H1 H2 8FT 2 4m 2 5FT 0 8m 10 5 FT 3 2m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2 5...

Страница 18: ...6FT 1 8m 2FT 0 6m 8 FT 2 4m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2 5m HT HR HO 8FT 2 4m 8 1FT 2 5m 16 1FT 4 9m HT VT 16 1FT 4 9m 4 5FT 1 4m 20 6 FT 6 3m Formula 1 HT 3VT 3VT 3FT 0 9m x 4 5FT 1 4m...

Страница 19: ...AS AND ELECTRICAL SUPPLY TO THE APPLIANCE FOR SAFE AND PROPER OPERATION OF THE APPLIANCE FOLLOW THE VENTING INSTRUCTIONS EXACTLY ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING...

Страница 20: ...is installed in its final position apply sealant between the pipe and the firestop assembly C In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will...

Страница 21: ...nt the additional length needed for the finished wall surface Apply a heavy bead of the high temperature sealant W573 0007 Mill Pac not supplied to the inner sleeve of the air terminal Slip the vent p...

Страница 22: ...ving a min 3 4 19mm of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is...

Страница 23: ...A 4 3 1 HORIZONTAL AIR TERMINAL INSTALLATION A Move the appliance into position Measure the vent length required between terminal and appliance taking into account the additional length needed for the...

Страница 24: ...mm margin all around Fasten to the roof Do NOT nail through the lower portion of the flashing Make weather tight by sealing with caulking Where possible cover the sides and top edges of the flashing w...

Страница 25: ...ding products contact your local authorized dealer distributor for the appropriate securing kit For mobile home installations the appliance must be fastened in place It is recommended that the applian...

Страница 26: ...EVENT DAMAGING GAS LINE ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A...

Страница 27: ...THICKNESS TO MAINTAIN CLEARANCES FRAMING OR FINISHING MATERIAL CLOSER THAN THE MINIMUMS LISTED MUST BE CONSTRUCTED ENTIRELY OF NON COMBUSTIBLE MATERIALS MATERIALS CONSISTING ENTIRELY OF STEEL IRON BR...

Страница 28: ...6 471mm ENCLOSURE TOP FINISHING MATERIAL ELECTRICAL CONNECTION 591 2 1511mm MIN 3 81 4 210mm 1 15 16 49mm STEEL STUD 35 1 2 902 mm STEEL STUD NON COMBUSTIBLE MATERIAL FRAMING DIMENSIONS Ref CX70 A 35...

Страница 29: ...any of the black face areas of the appliance Non combustible material brick stone or ceramic tile may protrude in these areas Minimum clearance to combustible construction from appliance and vent sur...

Страница 30: ...6mm COMBUSTIBLE NON COMBUSTIBLE BRICK 0 0MM IF NON COMBUSTIBLE FINISHINGISUSED SUCHASBRICK ANDSTONE 3 76mm MINIMUM 3 76mm 2 51mm 1 25mm 591 2 1511mm 78 1981mm CEILING MIN 189 16 471mm 4713 16 1214mm M...

Страница 31: ...47 13 16 1214mm 1 25mm 33 1 8 841mm 42 1066mm 78 1981mm 2 51mm 3 76mm FIRESTOP ASSEMBLY STEEL STUD FRAMING NON COMBUSTIBLE MATERIAL 0 0MM IF NON COMBUSTIBLE FINISHING MATERIAL IS USED SUCH AS BRICK AN...

Страница 32: ...e sides If greater projections are desired increase the clearance to the sides and top by 2 51mm for every additional 1 25mm of projection If using an optional surround the same rule applies starting...

Страница 33: ...UST BE HEAT RESISTANT TO PREVENT DISCOLOURATION 73 1 5 4 MINIMUM COMBUSTIBLE MANTEL CLEARANCES 0 3 4 7 14 16 1 2 5 6 12 7 0 1 7 MANTEL DEPTH 8 10 6 4 18 20 8 10 9 22 24 26 E D C B A TOP OF OPENING MAN...

Страница 34: ...TE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED FACING AND OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING 72 1A 6 1 LOG SHIPPING BRACKET Before installing the logs yo...

Страница 35: ...ss door can be removed the safety screen must be removed Lift the safety screen off the 4 pins tilt the top forward and remove from the appliance Leave a hand on the glass door during entire door remo...

Страница 36: ...ce the colours will become more uniform as colour pigments burn in during the heat activated curing process Blocked burner ports can cause an incorrect flame pattern 6 4 LOG PLACEMENT 1 PIN 2 PIN A Pl...

Страница 37: ...rts Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition PHAZERTM logs glow when exposed to direct flame Use only certified glowing embers and PHAZERTM logs a...

Страница 38: ...OT RESET BUTTON BATTERY HOLDER COMPLETE NIGHT LIGHT BLOWER WITH RESET BUTTON W190 0048 RECEIVER BLOWER NOTE This appliance is equipped with a three prong grounding plug for protection against shock ha...

Страница 39: ...ntil the thermo couple has cooled Allow approximately 60 seconds for the thermocouple to cool When lighting and re lighting the gas knob cannot be turned from pilot to off unless the knob is depressed...

Страница 40: ...alve clockwise to off Located behind the access panel G Wait five 5 minutes to clear out any gas If you smell gas including near the floor STOP Follow B in the above safety information on this label I...

Страница 41: ...ress the reset programming button use a small object such as a paper clip in order to reach the button marked PRG as shown in the illustration below D The battery holder will beep 3 times to indicate...

Страница 42: ...le the system is on but the flame is off the flame will come on the high position A single beep will confirm reception of the command 35 8A 76 F OFF 76 F 76 F 76 F Hi FLAME OFF FLAME AT LEVEL 1 FLAME...

Страница 43: ...is equipped with a CPI IPI toggle switch set the CPI IPI to CPI position to enable remote CPI operation If the switch is set to IPI then it will only work in IPI regardless of what is set on the remot...

Страница 44: ...g the remote B Install 4 AA batteries ensure that the positive and negative ends correspond with those identified in the battery holder C In the case of a power outage the 3 position slider switch nee...

Страница 45: ...ssure gauge tubing over the test point Gauge should read as described on the chart below Check that main burner is operating on HI Outlet pressure can be checked the same as above using screw B Gauge...

Страница 46: ...hich can be distributed in the surrounding living area F Check to see that the main burner ignites completely on all openings when turned on A 5 to 10 second total light up period is satisfactory If i...

Страница 47: ...is important that the pilot assembly is not painted Inspect all accessible gaskets and replace as required Access the blower if equipped and clean using a soft brush and vacuum Re assemble the various...

Страница 48: ...COUPLE SUPPLIED BY WOLF STEEL LTD WARNING 10 1 NIGHT LIGHT REPLACEMENT Your appliance came equipped with our NIGHT LIGHT The light has been pre wired and can be controlled from the switch on the contr...

Страница 49: ...the gasket holding the glass in place Careful not to break the glass WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED CARE MUST BE TAKEN WHEN REMOVING AND DISPO...

Страница 50: ...r Drywall dust will penetrate into the blower bearings causing irreparable damage Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resu...

Страница 51: ...570 0135 W635 0087 HOOD CONTINENTAL LOGO DOOR ASSEMBLY LOG SUPPORT 3 PRONGE ELECTRICAL BOX W010 3070 DOOR LATCHES X4 STAND OFFS X4 1 2 3 4 8 6 13 11 13 10 13 12 13 9 13 13 13 14 SHOULDER SCREWS X4 14...

Страница 52: ...VALVE TRAIN BASE W035 0404 W010 0799 PILOT ASSEMBLY LP W080 1601 PILOT BRACKET W080 1560 VALVE BRACKET W725 0026 VALVE LP W450 0036 PAL NUT 2 4 W290 0235 VENTURI HOUSING GASKET W350 0696 VENTURI HOUSI...

Страница 53: ...0057 VALVE LP W290 0235 VENTURI HOUSING GASKET W350 0696 VENTURI HOUSING W750 0268 BATTERY HOUSING WIRE HARNESS 16 17 18 19 20 21 22 23 W750 0358 FEMALE X4 ON OFF JUMPER W750 0159 BLOWER WIRE HARNESS...

Страница 54: ...0 15 GX70 ACCESSORIES H35F GX725WI GX427 47 48 TK35 W430 0003 MAGNET X16 TK35 YES W715 0953 TOP BOTTOM TRIM X2 TK35 W715 0952 SIDE TRIM X2 TK35 W475 1142 LS PORCELAIN PANEL PRPGX70 W475 1143 REAR PORC...

Страница 55: ...ed and plugged into the module Check voltage of the transformer under load at the spade connections on the module with the ON OFF switch in the ON position Acceptable readings of a good transformer ar...

Страница 56: ...me rectification Verify correct pilot orifice is installed and inlet gas specifications to manual Remember the flame carries the rectification current not the gas If the flame lifts from pilot hood th...

Страница 57: ...ctor plate See RESTRICTING VENTS section if applicable Main burner flame is a blue lazy transparent flame Blockage in vent Remove blockage In extreme conditions ice buildup may occur on the terminal a...

Страница 58: ...lace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch termin...

Страница 59: ...Gauge should read as described on the chart below Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak tes...

Страница 60: ...headaches Appliance is spilling Ensure exhaust bracket gasket seal Check door seal and relief flap seal Check for chimney blockage Check that chimney is installed to building code Room is in negative...

Страница 61: ...sufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to appliance combustion chamber heat e...

Страница 62: ......

Отзывы: