11
W415-0149 / B / 11.25.09
COMBUSTION AIR COVER
PLATES & GASKETS
INST
INST
INST
INST
INSTALLING 'B'
ALLING 'B'
ALLING 'B'
ALLING 'B'
ALLING 'B' VENT
VENT
VENT
VENT
VENT:::::
Follow the instructions for "Wall and Ceiling Protection".
ADAPTER INSTALLATION
1. Remove the spill switch bracket from the rear of the
adapter.
2. Gently pull the two wire terminals (located inside the 7"
flue collar at the top of the stove) out approximately 8 inches.
3. Bring the wires through the lower hole in the adapter and
out the spill switch opening. To pass the wires through the
hole more easily, temporarily tape the two terminals to-
gether.
4. With the spill switch opening aligned to the back of the
stove, push the crimped edge of the adapter into the stove
flue collar.
5. Connect the wire terminals to the spill switch and re-
secure the bracket.
6. Secure the terminal block into place as shown with the
screw supplied.
7. Unscrew the wire access cover plate from the rear right
hand side of the firebox. Remove and discard the gasket.
Remove the knockout from the cover plate and insert the
protective bushing. Pull both spill switch wires through the
bushing taking up any slack. Replace the cover plate.
Connect one wire end to the terminal block and the other
end to terminal 1 of the gas valve. Connect the two wires
running down the left side of the unit from the on-off switch
to the remaining tab on the terminal block and to terminal 3
on the gas valve.
CHIMNEY INSTALLATION
THREE TYPES OF
CHIMNEY SYSTEMS
MAY BE USED WITH
THIS STOVE:
B-VENT SPECIFICS - MODEL CS280
SWITCH
SPILL
ADAPTER
'B' VENT ADAPTATIONS
1. Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the unit.
2. Replace the four screws per side to secure the rear
panel to the unit.
TERMINAL BLOCK
TERMINAL BLOCK
WIRE ACCESS
WIRE ACCESS
WIRE ACCESS
WIRE ACCESS
WIRE ACCESS
CO
CO
CO
CO
COVER PLA
VER PLA
VER PLA
VER PLA
VER PLATE
TE
TE
TE
TE
Содержание CDVS 280-N