41
W415-0570 / E / 04.23.12
10.1 NIGHT LIGHT REPLACEMENT
Your appliance came equipped with our
“NIGHT LIGHT”. The light has been pre-wired
and can be controlled from the switch on the
control panel.
It is recommended that the NIGHT LIGHT
be in the off position when the appliance
is on.
If in the event the lamp or lens needs to be
replaced, follow the instructions below.
Unplug the light from inside the appliance.
Remove the four screws that secure the lens
frame. This frame retains the glass lens. The
lamp can now be accessed.
NOTE: Do not handle the lamp (bulb) with bare
fi ngers, protect with a clean dry cloth.
The lamp will pull straight out of the socket. Replace
with Wolf Steel parts only, as lamp and lens are spe-
cial “high temperature” products.
When re-installing, ensure integrity of gasket seal.
THE FIREBOX MUST BE SEALED.
NOTE: Over tightening the screws could break the lens.
“Light Leakage” from the upper louvre area may be noticed. The holes in the lamp housing are necessary for
ventilation and must not be covered.
SCREWS
LENS
ASSEMBLY
FIREBOX TOP
GASKET
LENS
FRAME
AMBER
SIDE UP
10.2 THERMAL SWITCH REPLACEMENT
RECEPTACLE /
THERMAL SWITCH
GROUND
SCREW
JUNCTIONBOX
The thermal switch is located to the left side of the
lower control area, on a bracket and mounted beside
the junction box.
A.
Unplug the blower from the junction box or turn
off the power to the appliance if hard wired.
B.
Remove the fastener. Pivot the bracket out
from the
fi
rebox side.
C.
Disconnect the slip-on connectors and remove
the thermal switch from the bracket.