1.

Turn off all electrical power to the unit if service is to be 

performed.

MAINTENANCE

FOR YOUR SAFETY READ BEFORE LIGHTING:

WHAT TO DO IF YOU SMELL GAS:

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

This fi replace has a pilot which must be lit by hand while 

following these instructions exactly.

Before lighting, smell all around the fi replace area for gas 

and next to the fl oor because some gas is heavier than air 
and will settle on the fl oor.

Use only your hand to push in or turn the gas control knob. 

Never use tools. If the knob will not push in or turn by hand, 

do not try to repair it. Call a qualifi ed service techni-
cian. Force or attempted repair may result in a fi re  or 
explosion.

Do not use this fi replace if any part has been under water. 

Immediately call a qualifi ed service technician to inspect 
the unit and replace any part of the control system and 
any gas control touched by water.

• 

 Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone 

in your building.

•  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier's instructions.

•  If you cannot reach your gas supplier, call the fi re depart-

ment.

1.Stop! 

Read all the safety information above. When lighting 

and re-lighting, the gas knob cannot be turned from "pilot" to 
"off" unless the knob is depressed.

2.

Turn off all electrical power to the stove.

3.

Turn the gas knob 

  clockwise to off.

4.

Wait 5 minutes for any gas in the combustion chamber to 

escape. Continue to the next step if you do NOT smell any 
gas. 

If you smell gas, STOP! 

and follow the instructions in  

"What to do if You Smell Gas" listed above.

5.

If the unit is equipped with a fl ame adjustment valve, turn 

 clockwise to off.

6.

Locate the pilot situated in front of the rear log.

7.

Turn the gas knob  

 counter-clockwise to  "pilot" posi-

tion.

8.

Depress and hold 

the gas knob while lighting the 

pilot with the push 

button ignitor. Keep the knob fully 

depressed for one (1) minute, then release. If the pilot does 
not continue to burn, repeat steps 3 through 7.

9.

With the pilot lit, turn the gas knob counter-clockwise to 

"on" position.

10.

If your insert is equipped with a fl ame adjustment valve, 

push and turn the knob to "high".

11.

If your insert is equipped with a remote "on-off" switch, the 

main burner may not come on when you turn the gas valve 
to "on" or "high".

 The remote switch must be in the "on" 

position as well to ignite the main burner.
12.

Turn on all electrical power to the insert.

2.

Push in gas control knob slightly and turn 

 clockwise 

to off. 

DO NOT FORCE.

TURN OFF THE GAS AND ELECTRICAL POWER 

BEFORE SERVICING THE FIREPLACE.

CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous 
operation. Verify proper operation after servicing. This insert 
and its venting system should be inspected before use and 
at least annually by a qualifi ed service person. The fi replace 
area must be kept clear and free of combustible materials, 
gasoline or other fl ammable vapours and liquids. The fl ow of 
combustion and ventilation air must not be obstructed.

1. 

 In order to properly clean the burner and pilot assembly, 

remove the logs to expose both assemblies.

2. 

 Keep the control compartment, logs, burner, air shutter 

opening and the area surrounding the logs clean by vacuum-
ing or brushing, 

at least once a year

.

3. 

 Check to see that all burner ports are burning. Clean out 

any of the ports which may not be burning or are not burning 
properly. 

4.  

Check to see that the pilot fl ame is large enough to engulf 

the thermopile on one leg and reaches toward the burner on 
the other leg.

5. 

 Replace the cleaned logs.

6. 

 Check to see that the main burner ignites completely on 

all openings when the gas knob for the burner is turned on. A 
5 to 10 second total light-up period is satisfactory. If ignition 
takes longer, consult your CONTINENTAL dealer / distributor.

7. 

Check that the door gasketing is not broken or missing. 

Replace if necessary.

Содержание CBI 360-N

Страница 1: ...mmediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perfor...

Страница 2: ...r other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It is imperative that the co...

Страница 3: ...material for life subject to the following conditions During the first 10 years CONTINEN TAL will replace or repair the defective parts at our option free of charge From 10 years to life CONTINENTAL...

Страница 4: ...ing of the fireplace This insert must be recessed into a vented noncombustible woodburning fireplace prefabricated or masonry only The minimum fireplace size in which the heater is to be installed is...

Страница 5: ...installing the insert Remove the existing fireplace damper or lock into an open position Using screws attach the fireplace warning tag W385 0199 to the inside of the firebox of the fireplace into whic...

Страница 6: ...ded maximum lead length depends on wire size WIRE SIZE MAX LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Attach the two leads to terminals 1 and 3 located on the gas valve Do not connect the...

Страница 7: ...ntered evenly above the pilot assembly 3 While supporting the back log to prevent it from fall ing forward set the three smaller logs into the pockets and grooves of the front and back logs respective...

Страница 8: ...LE DEATH A CHECK FOR CORRECT VENTING ACTION MUST BE MADE BEFORE THE INSTALLED INSERT IS LEFT WITH THE CUSTOMER Test after installing the unit into a vented non combustible fireplace in the following m...

Страница 9: ...g the pilot with the push button ignitor Keep the knob fully depressed for one 1 minute then release If the pilot does not continue to burn repeat steps 3 through 7 9 With the pilot lit turn the gas k...

Страница 10: ...up the back of the firebox and exhausted as hot air between the upper louvres Turn off the gas and electric power to the unit Remove the upper glass bracket Loosen the lower glass bracket and remove t...

Страница 11: ...XE 6 PORCELAIN FLASHING KIT ALMOND 26 GI 909K6 DELUXE 6 PORCELAIN FLASHING KIT BLACK 26 GI 909F6 DELUXE 6 PORCELAIN FLASHING KIT GREEN FOR OPENINGS SMALLER THAN 30 X 48 26 GI 900B9 DELUXE 9 FLASHING K...

Страница 12: ...12 W415 0120 F 10 25 11 20 12 9 15 26 39 38 16 14 1 2 5 6 4 3 21 13 10 11 27 33 34 37 35 36...

Страница 13: ...he valve call the gas distributor turn on all gas appliances and see if pilot flame flutters di minishes or extinguishes especially when main burners ignite Monitor supply pressure check if supply pip...

Страница 14: ...ney blockage check that chimney is installed to building code room is in negative pressure increase fresh air supply Fireplace is spilling reverse Remote wall switch is in off position main burner com...

Страница 15: ...15 W415 0120 F 10 25 11 43 1...

Страница 16: ...16 W415 0120 F 10 25 11 44 1 NOTES...

Отзывы: