background image

W415-1283 / E / 12.21.16 

 

 

 

RATING PLATE / LIGHTING INSTRUCTION LOCATION 

 

WARNING

 

ALLOW THE APPLIANCE TO COOL BEFORE PERFORMING ANY MAINTENANCE OR CLEANING. 

NOTE : Screen must be removed to access rating plate / lighting instructions. 

Both the rating plate and lighting instructions are attached to a cable and located behind the control panel of 
the appliance. Lift the access plate and control panel up and away from the appliance. With the cable at the 
bulb end of the slot, wiggle the rating plate out being careful not to tear the instructions. 

 

INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to 
the model, venting and gas type of the appliance. 

This illustration is for reference only. Refer to the rating plate on the appliance for accurate information. 

NOTE : The rating plate must remain with the appliance at all times. It must not be removed. 

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the 
appliance and must be installed. 

l’utilisateur pour plus de renseignements. Une 

REMPLACEMENT DU 

trousse de conversion est fournie avec cet 

PANNEAU À UN 

appareil.» 

TECHNICIEN 

AGRÉÉ. 

W385-1936 / A 

ANNEAU FRONTAL EN VERRE 

N’EST PAS EN PLACE, EST CRAQUÉ 

OU BRISÉ. CONFIEZ LE 

UTILISER L’APPAREIL SI LE 

FOR YOUR SAFETY: 

DO NOT STORE OR USE GASOLINE 
OR OTHER FLAMMABLE VAPORS 
AND LIQUIDS IN VICINITY OF THIS 

OR ANY OTHER APPLIANCE. 

CAUTION: 

DO NOT OPERATE 

THE APPLIANCE WITH THE GLASS 

REMOVED, CRACKED OR BROKEN. 

REPLACEMENT OF THE GLASS 

SHOULD BE DONE BY A LICENSED 

OR QUALIFIED PERSON. 

POUR VOTRE 

SÉCURITÉ: 

NE PAS ENTREPOSER NI UTILISER 

D’ESSENCE NI D’AUTRES VAPEURS 

OU LIQUIDES INFLAMMABLES 

DANS LE VOISINAGE DE CET 

APPAREIL OU DE TOUT AUTRE 

APPAREIL. 

AVERTISSEMENT: 

NE PAS 

“This appliance is only for use with the type(s) 

of gas indicated on the rating plate and may 

be installed in an aftermarket, permanently 
located, manufactured home (USA only) or 
mobile home, where not prohibited by local 

codes. See owner’s manual for details. This 

appliance is supplied with a conversion kit.” 

«Cet appareil doit être utilisé uniquement 

avec les types de gaz indiqués sur la plaque 

signalétique et peut être installé dans une 
maison préfabriquée (É.-U. seulement) ou 

mobile installée à demeure si les règlements 

locaux le permettent. Voir la notice de 

ATTENTION: 

UN INSTALLATION OU UNE 

MODIFICATION INAPPROPRIÉE 

DU RÉGLAGE, DU SERVICE ET DE 
L’ENTRETIEN POURRAIENT ÊTRE 

LA CAUSE DE DOMMAGES À LA 

PROPRIÉTÉ DE BLESSURES 

CORPORELLES OU MÊME LA 

MORT. CONSULTER LE MANUEL 

D’INFORMATION, L’INSTALLATION 

ET LE SERVICE DOIVENT 

ÊTRE EXECUTÉS PAR UN 

INSTALLATEUR  QUALIFIÉ POUR 

LE GAZ, UNE ENTREPRISE DE 

SERVICE OU LE FOURNISSEUR 

DE GAZ SEULEMENT. 

CAUTION: 

HOT WHILE OPERATING. DO NOT TOUCH. 

KEEP CHILDREN, CLOTHING, FURNITURE, 

GASOLINE OR OTHER FLAMMABLE VAPORS 

AWAY. 

AVERTISSEMENT: 

L’APPAREIL EST CHAUD PENDANT SON 
FONCTIONNEMENT.  LES ENFANTS, LES 

VÊTEMENTS, LES MEUBLES, 

L’ESSENCE ET 

AUTRES LIQUIDES QUI ÉMETTENT DES GAZ 

VOLATILS INFLAMMABLES DOIVENT 
ÊTRE TENUS ÉLOIGNÉS DE 

L’APPAREIL. 

WARNING: 

IMPROPER INSTALLATION, 

ADJUSTMENT, ALTERATION, 

SERVICE, OR MAINTENANCE 

CAN CAUSE PROPERTY DAMAGE, 

PERSONAL INJURY OR LOSS OF 

LIFE. REFER TO OWNER’S 

MANUAL. INSTALLATION AND 

SERVICE MUST BE PERFORMED 

BY A QUALIFIED INSTALLER, 

SERVICE AGENCY OR THE 

GAS SUPPLIER. 

GARDEZ LE BRÛLEUR ET LE 

COMPARTIMENT DES 

CONTRÔLES PROPRES. 

CONSULTEZ LE MANUEL 

D’INFORMATION ET 

D’INSTALLATION. PAR 

MESURE DE SÉCURITÉ. 

CET APPAREIL DOIT 

ÊTRE ALIMENTE EN AIR 

FRAIS ET AVEC SUFFISANT 

D’AIR COMBURANTET 

DE VENTILATION. 

KEEP BURNER AND CONTROL 

COMPARTMENT CLEAN. SEE 

INSTALLATION AND OPERATING 

INSTRUCTIONS MANUAL. 

APPLIANCE NEEDS FRESH 
AIR FOR SAFE OPERATION 

AND MUST BE INSTALLED 

WITH ADEQUATE PROVISIONS 

FOR COMBUSTION 

AND VENTILATION AIR. 

SPÉCIFICATIONS ÉLECTRIQUES : 115 V, 

W385-1936 / A

 

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA  

SERIAL NUMBER/ NO. DE SÉRIE:

  BHD4 

60HZ. MOINS DE 12 AMPÈRES. 

WOLF STEEL LTD. 

0” 
0” 
0” 
0” 

3” 

 

2” 
1” 

8”* 

DESSUS DU CONDUIT D‟EVENT 

CÔTÉS ET DESSOUS DU CONDUIT 

D‟EVENT 
CONDU

IT D‟EVENT VERTICAL 

TABLETTE 

LA MANUEL DE PROPRIÉTAIRE POUR LES MATÉRIAUX DE 
FINITION. *L’EXTENSION HORIZONTALE MAXIMALE : 2”. 
RÉFÉRER AU MANUAL D’INSTRUCTION POUR DES 
EXTENSIONS PLUS GRANDES. RÉFÉRER AU MANUEL 
D’INSTALLATION DE PROPRIÉTAIRE. 

TOP SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING 

MATERIALS. FOR FINISHING MATERIALS, SEE OWNER’S MANUAL 
*MAXIMUM HORIZONTAL EXTENSION / L’EXTENSION HORIZONTALE 
MAXIMALE: 2”. SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS. 

SEE OWNER’S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM LENGTHS. 

ELECTRICAL RATING: 115V.60HZ. LESS THAN 12 AMPERES 

CÔTÉS 

DÉGAGEMENT POUR LES MATÉRIAUX D’OSSATURE SELON ARRIÈRE 

PLANCHER 

LE MAINTIEN DU SYSTÉME DE PRISE D‟AIR. 

DESSUS, CÔTÉS & ARRIÈRE : SELON LES ESPACEURS DE 

COMBUSTIBLES : 

INTAKE 

SYSTEM. RÉINSTALLER ET RESCELLER L‟ÉVENT APRÉS AVOIR ASSURÉ 

DESSUS 

FOR VENTING SPECIFICS. PROPER REINSTALLATION AND 

AU MANUEL D’INSTALLATION DE PROPRIÉTAIRE POUR 

DÉGAGEMENTS MINIMAUX DES MATÉRIAUX 

RESEALING IS NECESSARY AFTER SERVICING THE VENT-

AIR L‟ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN 

THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE 

L‟APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT 

NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL L‟ENSEMBLE D‟ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER 

APPAREIL DE CHAUFFAGE

 

0” 

0” 

0” 

0” 

3” 

2” 

1” 

8”* 

TOP 

FLOOR 

SIDES 

BACK 

VENT TOP 
VENT SIDES & BOTTOM 
VERTICAL VENT 

MANTEL 

ÊTRÉ UTILISÉ AVEC CET APPAREIL. 
UTILISER AVEC LES PORTE VITRÉES 
HOMOLOGUÉES SEULEMENT AVEC 

CETTE APPAREIL. 

ADVERTISSEMENT : 

N‟AJOUTEZ PAS À 

CET APPAREIL AUCUN MATÉRIAU DEVANT 
ENTRER EN CONTACT AVEC LES FLAMMES 
AUTRE QUE CELUI QUI EST FOURNI AVECT CET 

APPAREIL PAR LE FABRICANT. 
PRODUIT DÉCORATIF: NE PAS UTILISER COMME 

MANIFOLD PRESSURE / 

10” WATER COLUMN/D’UNE COLONNE D’EAU 

PRESSION AU COLLECTEUR 

MINIMUM SUPPLY PRESSURE / 

11” WATER COLUMN/D’UNE COLONNE D’EAU 

PRESSION D’ALIMENTATION MINIMALE 

MAXIMUM SUPPLY PRESSURE 

13” WATER COLUMN/D‟UNE COLONNE D‟EAU 

PRESSION D’ALIMENTATION MAXIMALE 

P.4 

67.9% 

7.0“ WATER COLUMN/D’UNE COLONNE D’EAU 

 

67.9% 

4.5“ WATER COLUMN/D’UNE COLONNE D’EAU 

WITH THE APPLIANCE. 

DECORATIVE PRODUCT: NOT FOR USE AS A 

HEATING APPLIANCE 

MINIMUM CLEARANCE TO 

COMBUSTIBLE MATERIALS: 

CONTACT WITH THE FLAMES, OTHER THAN 

3.5” WATER COLUMN/D‟UNE COLONNE D‟EAU 

THAT SUPPLIED BY THE MANUFACTURER 

23,000 BTU/H  REDUCED INPUT / ALIMENTATION RÉDUITE  23

,000 BTU/H 

TO THE APPLIANCE, WHICH WILL COME IN 

30,000 BTU/H 

INPUT / ALIMENTATION 

30,000 BTU/H 

BHD4P 

ALTITUDE / ÉLÉVATION 

0-4500FT (0-1370M) 

CET FOYER À GAZ VENTILÉ N'EST 

MODEL PROPANE / 

PAS POUR L'USAGE AVEC LES 

PROPANE MODÈLE 

FILTRES D'AIR. 

UN COMBUSTIBLE SOLIDE NE PAS 

CBHD4P 

CBHD4N 

GAZ NATUREL 

BHD4N 

0-4500FT (0-1370M) 

NOT FOR USE WITH AIR FILTERS. 

NOT FOR USE WITH SOLID FUEL. 

FOR USE WITH GLASS DOORS 

CERTIFIED WITH THIS APPLIANCE 

ONLY. 

WARNING: 

DO NOT ADD ANY MATERIAL 

THIS VENTED GAS FIREPLACE IS 

MODEL NATURAL GAS / 

MESURES DE SÉCURITÉ CONTRE L’INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. THIS APPLIANCE MUST BE INSTALLED IN 
ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT ANSI Z223.1 OR CSA B149, INSTALLATION CODES. INSTALLER L’APPAREIL SELON LES CODES D’INSTALLATION ANSI Z223.1 OU 
CSA-B149 EN VIGUER. 

POUR CANADA / USA 

REFERENCE # 161746 

CERTIFIED UNDER / HOMOLOGUÉ SELON LES NORMES: ANSI Z21.50b - 

2009 • CSA 2.22b - 2009 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ 

VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT 
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTIO N AND SAFETY STANDARD, TITLE 24 CFR, PART 
3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. FOYER À 
GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION 
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ EN VIGEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SÉCURITÉ ET DE CONSTRUC- 

CERTIFIED FOR / CERTIFIEE 

TION DE MAISONS MANUFACTURÉE, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D’ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE  

C E R T I F I E D

 

 

EN 

Содержание CBHD4N

Страница 1: ...may result causing property damage personal injury or loss of life HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk...

Страница 2: ...FRAMING CBHD4ST 28 PENINSULA FRAMING CBHD4P 28 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES 29 SEE THRU CBHD4ST 29 PENINSULA CBHD4P 29 INSTALLING COMBUSTIBLE BOARD 30 FINISHING SUPPORT ADJUSTMENT 31 N...

Страница 3: ...in the margin 1 0 INSTALLATION OVERVIEW COMBUSTIBLE MATERIAL Framing see FRAMING section Mantel see MINIMUM MANTEL CLEARANCES section Venting see VENTING section Door see END DOOR INSTALLATION sectio...

Страница 4: ...fore use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc The appliance area must be kept clear and...

Страница 5: ...FETY BARRIER 34 3 16 868mm 38 1 4 841mm 2 1 16 53mm RIGHT SIDE LEFT SIDE 43 1 4 1099mm 79 16 192mm GASINLET 7 9 16 192mm ELECTRIC AL INLET 8 203mm 5 127mm 25 1 8 638mm 12 13 16 325mm SAFETY BARRIER 34...

Страница 6: ...ting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood pan...

Страница 7: ...ELECTRONIC IGNITION When the appliance is installed at elevations above 4 500 ft 1372m and in the absence of specific recommendations from the local authority having jurisdiction the certified high al...

Страница 8: ...ITION L EXTENSION HORIZONTALE MAXIMALE 2 R F RER AU MANUAL D INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES R F RER AU MANUEL D INSTALLATION DE PROPRI TAIRE TOP SIDES BACK PER STAND OFF SPACERS FOR FRAM...

Страница 9: ...ke vent pipes Utilizing alternate constructions such as a chimney as part of the vent system is not permitted 7 2C You may reduce the appliance from 5 8 venting to 4 7 venting for horizontal and verti...

Страница 10: ...structed at all times Examine the air terminal at least once a year to verify that it is unobstructed and undamaged Rigid and flexible venting systems must not be combined Different venting manufactur...

Страница 11: ...un must be kept to a maximum of 20 feet 6m If a 20 foot 6m horizontal run is required the appliance must have a minimum vertical rise off the appliance of 57 144 8cm When terminating vertically the ve...

Страница 12: ...cm is 10 3 1m for a replace and 8 2 4m for a stove MIN TO GRADE 24 61cm MIN REGARDLESS OF HORIZONTAL VENT LENGTH 38 1 4 97 2cm REDUCED VENT CLEARANCE TO COMBUSTIBLES 9 5B The minimum clearances around...

Страница 13: ...E 12 21 16 13 2 X3 USEMILLPACTOSEALADAPTERTOTHEAPPLIANCECOLLARS 3 4 X3 USEMILLPACTOSEALADAPTERTOTHEAPPLIANCECOLLARS 5 6 X3 USEMILLPACTOSEALADAPTERTOTHEAPPLIANCECOLLARS CONVERTING FROM 5 8 TO 4 7 VENT...

Страница 14: ...a porch or deck N 16 40 6cm 16 40 6cm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without ope...

Страница 15: ...hs Hr and offsets Ho in feet HR combined horizontal vent lengths in feet HO offset factor 03 total degrees of offset 135 in feet VT combined vertical vent lengths in feet ELBOW VENT LENGTH VALUES FEET...

Страница 16: ...epresents acceptable values for HT and VT For vent configurations requiring more than one 45 elbow and 90 elbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12 2m Example V1 8...

Страница 17: ...lowing formulas apply Formula 1 HT 4 2 VT Formula 2 HT VT 24 75 feet 7 5m Example 90 90 90 H H4 3 V H1 H 2 V1 4 FT 1 2m 2 90 V2 1 5 FT 0 5m V VT V1 V2 4 FT 1 2m 1 5 FT 0 5m 5 5 FT 1 7m H1 2 FT 0 6m H2...

Страница 18: ...configurations requiring more than one 45 and one 90 elbow the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12 2m Example V2 V1 5 FT 1 5m V2 10 FT 3 1m VT V1 V2 5 FT 1 5m 10 FT 3...

Страница 19: ...T 4 1m HT VT 13 4FT 4 1m 2 5FT 0 8m 15 9FT 4 8m Formula 1 HT 3VT 3VT 3FT 0 9m x 2 5FT 0 8m 7 5FT 2 3m 13 4 FT 4 1m 7 5 FT 2 3m Since this formula is not met this vent configuration is unacceptable For...

Страница 20: ...DE THE FIREBOX PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE OFF POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICA...

Страница 21: ...ne the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1 25mm clearance between the vent pipe and any combustible material Try to...

Страница 22: ...22 W415 1283 E 12 21 16 ound the pipe 21 1B COLLAR VENT PIPE SHIELD...

Страница 23: ......

Страница 24: ...ac not supplied must be used on the joint connecting the inner flex pipe and the exhaust flue collar Use only approved flexible vent pipe kits marked Wolf Steel Approved Venting as identified by the s...

Страница 25: ...ecure to the exterior wall and make weather tight by sealing with caulking notsupplied D If more vent pipe needs to be used to reach the fireplace couple them together as illustrated The vent system m...

Страница 26: ...terminal connector making sure the vent pipe goes into the hole in the terminal Secure with the three screws provided G Apply a heavy bead of weatherproof caulking 2 51mm above the flashing Install th...

Страница 27: ...crews inserted through the holes in the base to secure For free standing products contact your local authorized dealer distributor for the appropriate securing kit For mobile home installations the ap...

Страница 28: ...n and door from the appliance see SIDE SCREEN REMOVAL DOOR REMOVAL section B Remove media and media tray from the appliance see CRADLE BURNER REMOVAL section C Unscrew the 2 screws that hold the acces...

Страница 29: ...um clearances to combustibles from appliance and vent surfaces Combustible Appliance framing WARNING RISK OF FIRE IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CO...

Страница 30: ...4 1 8 61 3cm 5 1 2 PENINSULA FRAMING CBHD4P A MIN 22 1 8 56 2cm MAX 24 1 8 61 3cm B MIN 42 1 2 108cm MAX 43 1 2 110 5cm 46 1 2 118cm NOTE All framing dimensions are based on the finishing material sup...

Страница 31: ...3 76mm 62 1 4 158cm MINIMUM TOCEILING 50 11 3 4 298mm FIRESTOP 2 51mm 127cm MINIMUM ENCLOSURE 38 1 4 SAFETY BARRIER 43 109 2cm MINIMUM RISE 97 2cm 6 152mm MINIMUM WALL PENINSULA CBHD4P 45 114 3cm 3 7...

Страница 32: ...es and grouting We recommend you use tiles with a dry butt joint to be installed using a two part mortar with an acrylic latex additive such as Mapei Kerabond Kerlastic to allow for slight movement in...

Страница 33: ...s been installed Loosen the 8 screws on each finishing support Adjust the EN finishing support to the desired position NOTE Peninsula models have one end support that can also be adjusted by loosening...

Страница 34: ...jections are desired increase the clearance to the sides and top by 2 50 8mm for every additional 1 25 4mm of projection If using an optional surround the same rule applies starting from the top of th...

Страница 35: ...IMUM MANTEL CLEARANCES WARNING RISK OF FIRE MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT EN...

Страница 36: ...Y NON COMBUSTIBLE MATERIALS SUCH AS BRICK MARBLE GRANITE ETC PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE APP...

Страница 37: ...y screens must be removed prior to end screen removal see MAIN SAFETY SCREEN REMOVAL INSTALLATION section EN A Remove the 4 securing screws from the top and bottom of the end screen retainer refer to...

Страница 38: ...oor forward and out of the bottom door retainer E Reverse this process to install the door FIG 1 FIG 2 LATCHES IMPORTANT Once latches areengaged test that the door is secure and will not fall forward...

Страница 39: ...d on the door from the inside of the appliance at all times to prevent it from falling B Tilt the door from the top downwards and carefully remove it from the appliance C To install the end door rever...

Страница 40: ...ft side log support as shown in Figure 2 Place one pin into the middle of log 2 as shown in Figure 2 4 Place log 3 onto the pin located in log 2 and let it rest on log 2 as shown in Figure 3 and in th...

Страница 41: ...log support see CHARCOAL EMBERS section Use illustration below asreference 16 Place the charcoal lumps on top of the charcoal embers see CHARCOAL LUMPS section Use illustration below as reference NOTE...

Страница 42: ...CE ANY MEDIA GLASS OR VERMICULITE IN OR AROUND THE PILOT OPENING THIS WILL INTERFERE WITH THE PILOT OPERATION Evenly spread the glass media onto the media tray ensuring no glass media falls into the p...

Страница 43: ...CE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT RISK OF ELECTRICAL SHOCK OR EXPLOSION DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH INCORRECT WIRING WILL DAMAGE CONTROLS ALL WIRING S...

Страница 44: ...Canada or the ANSI NFPA national electrical code in the United States WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH This appliance comes equipped with a battery back up If this back up is...

Страница 45: ...you to easily access the battery housing C Remove your battery housing to install the batteries this will be located in the control compartment as shown below D Install the four AA batteries ensure th...

Страница 46: ...UME AUTOMATIQUEMENT LA VEILLEUSE NE TENTEZ PAS D ALLUMER LA VEILLEUSE MANUELLEMENT B AVANT DE FAIRE FONCTIONNER RENIFLEZ TOUT AUTOUR DE L APPAREIL POUR D CELER UN ODEUR DE GAZ RENIFLEZ PR S DU PLANCHE...

Страница 47: ...mprove the start up operation on colder climate days Therefore we recommend switching to the standing pilot on those colder days The anti condensation switch standing pilot is located in the control c...

Страница 48: ...ME SENSOR PILOT BURNER occurred remove the paint from the pilot assembly or replace Fine emery cloth or sandpaper can be used to remove the paint from the pilot hood electrode and ame sensor FLAME MUS...

Страница 49: ...em to the illustration provided If any flames appear abnormal call a service person ELECTRODE 3 8 1 2 9 5mm 3 1 2 8 7m 1 m 2 9 5mm 12 7mm ELECTRO FD LA EME SENSOR PILOT BURNER PILOT EN BURNER LAME MUS...

Страница 50: ...ee that the pilot flame is large enough to engulf the flame sensor and or thermocouple thermopile as well as reaches the burner E Replace the cleaned logs rocks or glass Failure to properly position t...

Страница 51: ...equipped and clean using a soft brush and vacuum Re assemble the various components in reverse order Inspect the relief system The appliance relieves through the main glass door or through the flaps o...

Страница 52: ...from the object may be deposited onto the coating which results in a discoloured stain or scratch like mark Such marks are not removed using the normal cleaning procedures given but require specializ...

Страница 53: ...rse these steps NOTE When reinstalling the burner ensure that the venturi rests on the orifice GLASS BURNER REMOVAL A Remove the main door s from the appliance see MAIN DOORREMOVAL INSTALLATION sectio...

Страница 54: ...nough to access the manual shut off valve and turn to the off position Disconnect the flex connector from the valve You may now lift the valve train out of the appliance RESTRICTING VERTICAL VENTS Ver...

Страница 55: ...rt Finish PARTS PART NUMBERS AND AVAILABILITY ARE SUBJECT TO CHANGE WITHOUT NOTICE PARTS IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN 2 TO 5 BUSINESS DAYS FOR MOST DELIVERY DESTINATIONS PARTS NOT ID...

Страница 56: ...SSEMBLY REF NO PART NUMBER DESCRIPTION STOCKED 1 W010 3209 SER RS CONTROL PANEL ASSEMBLY 2 W565 0264 SER MAIN DOOR SAFETY SCREEN 3 W562 0068 DOOR GASKET ASSEMBLY YES 4 W010 3205 MAIN DOOR ASSEMBLY 5 W...

Страница 57: ...W100 0160 GLASS BURNER ASSEMBLY YES 9 W010 3206 GLASS BURNER VALVE TRAIN ASSY REF NO PART NUMBER DESCRIPTION STOCKED 10 W655 0519 SER LOG SUPPORT 11 W710 0059 SER GLASS MEDIA TRAY 12 W010 2829 DOOR LA...

Страница 58: ...O PART NUMBER DESCRIPTION STOCKED 1 W010 2954 SER BURNER ASSEMBLY 2 W080 1400 SER BURNER BRACKET 3 W290 0018 VENTURI GASKET YES 4 W720 0005 VENTURI 1 2 3 4 ITEMS MAY NOT APPEAR EXACTLY AS ILLUSTRATED...

Страница 59: ...024 PILOT ASSEMBLY P YES 3 W290 0157 MANIFOLD GASKET YES 11 W080 1304 SER PILOT BRACKET 4 W105 0001 BUSHING 12 W035 0337 SER VALVE TRAIN BASE 5 W010 1985 WIRE HARNESS ASSEMBLY YES 13 W200 0456 VALVE A...

Страница 60: ...R ASSEMBLY 2 W080 1463 BURNER BRACKET 3 W290 0018 VENTURI GASKET YES REF NO PART NUMBER DESCRIPTION STOCKED 4 W720 0005 VENTURI 5 W080 1399 BURNER BRACKET LOG BURNER ASSEMBLY 1 2 3 4 5 ITEMS MAY NOT A...

Страница 61: ...TOR 16 W175 0217 FLEX CONNECTOR C W VALVE YES REF NO PART NUMBER DESCRIPTION STOCKED 1 W432 0103 GAS MANIFOLD 2 W456 0037 BURNER ORIFICE 37 NG YES 2 W456 0052 BURNER ORIFICE 52 P YES 3 W290 0157 MANIF...

Страница 62: ...YES 9 W135 0529 LOG 3 GL 688 YES REF NO PART NUMBER DESCRIPTION STOCKED 10 W135 0530 LOG 4 GL 688 YES 11 W135 0531 LOG 5 GL 688 YES 12 W135 0532 LOG 6 GL 688 YES 13 W135 0533 LOG 7 GL 688 YES 14 W135...

Страница 63: ...ch wire in wiring harness Battery backup Check batteries Improper switch wiring Troubleshoot the system with the simplest ON OFF switch Pilot sparks but will not light Gas supply Verify that the incom...

Страница 64: ...lve Tomeasure voltages turn the multimeter to DC place the red lead from the multimeter to the screw on the terminal block for the wire you are checking touch black lead to ground valve body Important...

Страница 65: ...any incidental consequential or indirect damages This warranty de nes the obligations and liability of CONTINENTAL with respect to the CONTINENTAL gas appliance and any other warranties expressed or i...

Страница 66: ......

Страница 67: ...65 W415 1283 E 12 21 16...

Отзывы: