W415-1283 / E / 12.21.16
38
LOG PLACEMENT
EN
76.1A
NOTE: The individual logs can be easily identified by the numbers cast on the underside of each log.
Phazer
TM
logs and glowing embers, exclusive to Wolf Steel Ltd., provide
a unique and realistic glowing effect that is different in every installation.
During the initial use of the appliance, log colours may vary. During the
initial use of the appliance, the colours will become more uniform as
colour pigments burn in during the heat activated curing process.
Blocked burner ports can cause an incorrect flame pattern.
NOTE: The pilot is located on the right end in these instructions.
1.
Remove the main safety screens and doors, see "MAIN SAFETY
SCREEN REMOVAL/INSTALLATION" and "MAIN DOOR REMOVAL/
INSTALLATION" sections for removal instructions.
2.
Line the hole in the bottom of log #1 with the screw and spacer in
the log support. Then place onto the screw and spacer located in the
corner of the burner, on the right side. Place a pin into the center of
log #1, as shown in Figure 1.
3.
Place log #2 onto the pin located in the log #1, it should rest in the
middle of the left side log support as shown in Figure 2. Place one pin
into the middle of log #2, as shown in Figure 2.
4.
Place log #3 onto the pin located in log #2 and let it rest on log #2, as
shown in Figure 3 and in the left side view below. Place another pin
into log #2, as shown in Figure 3.
5.
Place log #4 onto the pin located in log #2 and let it rest on log #2, as
shown in Figure 4 and in the left side view.
6.
Place log #5 onto the screw and spacer located in the left side log
support and let it rest on the burner, as shown in Figure 5.
NOTE: Ensure log #5 does not cover any burner ports.
7.
Place log #6 onto the pin located on the right side corner of the
burner, then place one pin into middle of the log #6 and log #5, as
shown in Figure 6.
NOTE: Ensure log #6 does not cover any burner ports.
LEFT SIDE VIEW
10
11
6
1
8
7
5
2
3
4
PIN
PIN
Fig. 6
Fig. 5
SCREW / SPACER
Fig. 1
PIN
Fig. 3
PIN
Fig. 2
Fig. 4
SCREW / SPACER
!
WARNING
FAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE
ONLY LOGS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY
DAMAGE OR PERSONAL INJURY.
LOGS MUST BE PLACED IN THEIR EXACT LOCATION IN THE APPLIANCE. DO NOT MODIFY THE
PROPER LOG POSITIONS, SINCE APPLIANCE MAY NOT FUNCTION PROPERLY AND DELAYED
IGNITION MAY OCCUR.
THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE.
Содержание CBHD4N
Страница 22: ...22 W415 1283 E 12 21 16 ound the pipe 21 1B COLLAR VENT PIPE SHIELD...
Страница 23: ......
Страница 66: ......
Страница 67: ...65 W415 1283 E 12 21 16...