7
W415-1616 / C / 09.20.17
EN
2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
CB46 RATES AND EFFICIENCIES
NG
P
Altitude (FT)
0-4,500
0-4,500
Max. Input (BTU/HR)
22,000
22,000
Min. Inlet Gas Supply Pressure
4.5" (11mb) Water Column
11" (27mb) Water Column
Max. Inlet Gas Supply Pressure
13" (32mb) Water Column
13" (32mb) Water Column
Manifold Pressure (Under Full
Flow Conditions)
3.5" (9mb) Water Column
10" (25mb) Water Column
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for
mobile home installation.
PRODUCT CODE CB46NTR AND CB46PTR ONLY : No external electricity (110 volts or 24 volts) is
required for the gas system operation. However, it is required with the installation of an optional
blower.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
CB46 PRODUCT CODE DESIGNATIONS
FUEL TYPE
OPERATING SYSTEM
CB46NTR
NATURAL
MILLIVOLT
CB46NTRE
NATURAL
ELECTRONIC IGNITION
CB46PTR
PROPANE
MILLIVOLT
CB46PTRE
PROPANE
ELECTRONIC IGNITION