45
W415-1616 / C / 09.20.17
EN
Combustible mantel clearance can vary according to the mantel depth. Use the graph
to help evaluate the clearance needed. These same requirements apply to any
combustibles protruding on either side of the appliance.
TOP OF APPLIANCE
6" 152mm
8"8" 203mm MANTEL
1" 25mm
2"
51mm
3"
76mm
4"
102mm
4" 102mm
2" 51mm
TOP OF APPLIANCE
OPENING
6" 152mm
8"8" 203mm MANTEL
2" 51mm
4"
102mm
6"
152mm
8"
203mm
4" 102mm
2" 51mm
TOP OF APPLIANCE
6" 152mm
8"8" 203mm MANTEL
1" 25mm
2"
51mm
3"
76mm
4"
102mm
4" 102mm
2" 51mm
!
WARNING
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
73.1
5.6 MINIMUM MANTEL CLEARANCES
MANTEL HEIGHT
0
2" (50.8mm)
2 4 6 8 10 12
MANTEL DEPTH (INCHES)
4" (101.6mm)
6" (152.4mm)
10" (254mm)
12" (30.5cm)
8" (203.2mm)
5.7 NAILING TAB INSTALLATION
55.3
A.
To determine the fi nal location and where to bend the nailing tabs you must fi rst determine the
thickness of your fi nishing material (i.e. drywall). This will determine the dimension from the
front edge of the corner post to the nailing tab. Once the desired tab has been choosen, bend
and secure to the framing.
1/2” FINISHING
MATERIAL
3/4” FINISHING
MATERIAL
34 5/8"
[87.9cm]
Содержание CB46NTR
Страница 5: ...5 W415 1616 C 09 20 17 EN 2 1 DIMENSIONS ...
Страница 71: ...16 0 NOTES 44 1 ...
Страница 77: ...77 W415 1616 C 09 20 17 FR 2 1 DIMENSIONS ENTRÉE DE GAZ ÉCRAN DE PROTECTION ...
Страница 143: ...143 W415 1616 C 09 20 17 FR 16 0 NOTES 44 1 ...