![Conti X-one Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/conti/x-one/x-one_technical-documents_2656565005.webp)
Edition 05/2014 - X-ONE - page 5
SACOME, CONFIDENTIAL Document,
it is forbidden to duplicate or communicate this document without previous authorization.
4
INSTALLATION
4.1 IN CASE OF A STANDBY OF THE MACHINE (STANDBY = 2 MONTHS):
The first thing to do is to test your machine in a lab.
If the machine stop ruming for a long time, you could have scale in some places.
More precisely in small area like the spray nozzle.
4.2 PROTECTIONS
It is necessary to place before the machine:
o
A water shutoff valve.
o
An electrical protection standard, suitable for voltage and power consumption.
4.3 WATER SUPPLY
Recommended operating pressure from 1.5 MPa to 6 MPa
Water connection pin 3/8"
The water supply pipes must resist to 145 Psi / 10 MPa
4.4 DRAIN
Sans pression.
Spigot at the outlet of the machine and a pipe is supplied with the machine
Ensure a connection that causes no risk of fluid return, and ensure good drainage:
The drain pipe must be located lower than the machine.
Do not create a bend in the exhaust tube.
4.5 SUPPLYING VOLTAGE
To be specify when ordering :
230V – 50/60Hz Monofase
Or :
400V – 50/60Hz Trifase