2.9.4
Superior Motor Delivery Position Impulses
To program the position of the maximum discharge of the superior piston (before stop 555).
In the factory the piston is programmed to stop his stroke at 555 increments.
When this value is not reached at the downstroke of the piston, the machine considers that the
piston is outside of the infusion chamber.
The display will show:
(No access to this menu with the technical card)
2.9.5
Maximum Inferior Motor Impulses
To programm the number of increments of the complete stroke of the inferior motor.
The value is programmed at the factory at 552
(No access to this menu with the technical card)
2.9.6
Inferior Motor Expel Impulses
To programm number of increments of the inferior piston to reach the ejection position.
The value is programmed at the factory at 532
(No access to this menu with the technical card)
2.9.7
Inferior Motor Grinding position impulses
To programm the minimum back distance of the inferior piston before stop 0.
The value is programmed at the factory at 20 increments before Zero.
To avoid that the piston comes up against the stop
(No access to this menu with the technical card)
2.9.8
No Coffee Infusion Impulses
To programm the position of the maximum exits acceptable of the inferior piston when packing the coffee.
Above, the machine will consider that there is no coffee in the chamber and the display will show: