Conti MONTE-CARLO Скачать руководство пользователя страница 1

 

MONTE-CARLO - 11/2015 - SOFT V 2.11 

 

 

 

 
 
 

 

 
 

TECHNICAL  DOCUMENTATION 

 

 

Содержание MONTE-CARLO

Страница 1: ...MONTE CARLO 11 2015 SOFT V 2 11 1 TECHNICAL DOCUMENTATION...

Страница 2: ...Mode menu 13 8 2 Group eco mode 15 8 3 Clean button 15 9 PROGRAMMING DOSES METHODOLOGY 16 9 1 Coffee doses programming 16 9 2 Hot water dose programming 17 10 GENERAL DISPLAY 18 10 1 ECO MODE general...

Страница 3: ...0 6700 MC 3G 14 6000 0 9 3 1000 3 100 300 9600 MC 2G K 10 6000 0 9 2 2500 2 100 300 11500 MC 3G K 14 6000 0 9 3 2500 3 100 300 14100 BOILER CAPACITY IN LITERS 2 Groups 3 Groups TOTAL 10 14 Hot water v...

Страница 4: ...sconnection from the main supply having a contact separation of at least 3mm in all poles must be provided in the fixed wiring in accordance with the installation rules 3 3 During the use When the mac...

Страница 5: ...lectrical protection standard suitable for voltage and power consumption 4 3 Water supply Recommended operating pressure from 1 5 MPa to 6 MPa Water connection pin 3 8 The water supply pipes must resi...

Страница 6: ...sponsible for limestone formation o It is measured with chemical dropper testers o The unit of measurment is Carbonate KH There are 2 types of water treatments Salt water softeners o They treat the to...

Страница 7: ...drip tray C During 1 second The general display shows the software version Monte Carlo 2 11 D According the situation the display shows E Enter the password to access the first installation as follows...

Страница 8: ...the 1 installation During this time the air inside coffee groups are automatically vaccum by an opening cycle of vaccum valves pump and groups valves G The process is finished when the display shows...

Страница 9: ...emperature setting of coffee boilers is reached 2 or 3 minutes automatic purge goes on The leds stay On General display blinking D When the steam boiler temperature reaches 105 C hot water button ligh...

Страница 10: ...display When the machine is ready the general display shows Boiler pressure bar Pressure network pump pressure Level information In progress Press where you want on the display during 3 sec to switch...

Страница 11: ...o be used to sterilise and warm glasses After each use and absolutely after heating milk always clean the stainless steel steam nozzle and the outlet nozzles with a damp cloth removing all traces pres...

Страница 12: ...ely To empty the coffee filters used turn the filter holder upside down and lightly tap it on the edge of a wooden box Never strike it against metal or other hard objects DIGITAL MANOMETER M1 BOILER P...

Страница 13: ...he Menu Enter button to enter in the programming mode The Esc button is used to escape from the programming mode MENU ENTER Esc 95 C Coffee boiler T Group temperature MENU A Pre brewing Dose setting M...

Страница 14: ...setting ENTER Dose setting ESC All the leds are OFF It is enough to program the left group so that both groups are configured in the same way Do the dose and stop at the desired volume When the dose...

Страница 15: ...CLEAN button the cleaning cycle starts Prepare the blind filter holder and cleaning tablet Put it on the group head Press the CLEAN button The machine starts the cleaning cycle without any special ind...

Страница 16: ...doses according to the programmed key in the suitable filter holder Press the MENU key the display show Coffee boiler T Press 2 times the key the display shows Doses setting Press the MENU key the di...

Страница 17: ...outlet Press key the coffee MENU from the group nearest the outlet to be programmed the display show Coffee boiler T Press 2 times the key the display shows Doses setting Press the MENU key the displ...

Страница 18: ...econds 10 2 Programming on general display If a password is not entered the steps available are only those marked with To access to the complete menu go to the last step Password and enter the good pa...

Страница 19: ...s to define the maximum power supply available for the machine Exemple 2 Max 22 Amp see chapter power management To select the group 2 or 3 group Machine version N group 2 To validate Next step Machin...

Страница 20: ...it solo system the machine need to be adjusted with a filling up with pump 10 2 5 3 Probe sensitivity Technical Par Next step To access to the following sub menu The display backlighting change on the...

Страница 21: ...validate Next step To adjust the value Range 5 to 80 min T Ri C Steam T Ri C Steam 80min To validate Next step To adjust the value Range 2 to 15 min T Ri C Coffee T Ri C Coffee 15min Next step To adj...

Страница 22: ...o the next character To escape Service Service Name Monte Carlo To validate Next step Service Phone To validate To change the character To move to the next character To escape To select To validate To...

Страница 23: ...ect To validate To escape Filters Alarm Reset Filters Alarm Reset NO Filtres Reset Alarme Yes To validate To select To validate To escape To change To select To validate To escape Service Alarm Reset...

Страница 24: ...MONTE CARLO 11 2015 SOFT V 2 11 24 10 2 5 12 Unit of measurments To escape Unit of measure Next step...

Страница 25: ...ll be the Setting T value o If the value is Actual The temperature shown on each coffee group displays will be the real temperature inside the coffee boilers o If the value is Average The temperature...

Страница 26: ...this one represents cups logos o If the user chooses Time Volume Flow The viewing during the extraction is this one ZZ ml s is the flow in ml s It s YYY on XX on 2 digits If the user chooses Quality c...

Страница 27: ...ue Range 80 to 95 C the temperature shown is the setting T of the left group the choosen setting temperature is validated for all the groups Temperature Gr 95 C Kp Ks Kd 1 0 0 6 0 To adjust the value...

Страница 28: ...iler temperature Temp Boiler Temp Boiler 123 C Next step PID setting 5 C To adjust the value Range 2 to 5 C To adjust the value Range 80 to 125 C Kp Ks Kd 3 8 0 04 10 0 To adjust the value To validate...

Страница 29: ...remain switched OFF 2 days are programmable If the value is OFF there is no closed day Set clock Fri 05 01 15 16 49 Next step To adjust the value To validate and proceed Auto ON OFF Auto ON OFF NO To...

Страница 30: ...the pre brewing 10 2 13 Steam Control See chapter Steam control adjustments To select Range Enable Disable Doses Setting Doses Setting Enable To validate To select Range Enable Disable Prebrewing Preb...

Страница 31: ...that the value of the pump pressure 10 2 15 Service 10 2 16 Water Filter To adjust the value Range 0 to 99900 Service Service cycles 0 Next step To adjust the value Range 0 to 10000 Water Filter Wate...

Страница 32: ...d in the 1 head group R grp 2 ZZ C Real temperature read in the 2 head group R grp 3 ZZ C Real temperature read in the 3 head group Pump Pump motor Filling up valve Filling up valve for steam boiler C...

Страница 33: ...t Reset NO To select Range Yes No If Yes If No Data Reset Completed To select Yes or No To validate Next step Press to know the amount of each product Coffee counters Espresso 1589 Next step To see th...

Страница 34: ...TE CARLO 2 11 20 05 15 Next step To come back USB Interface Next step See chapter How to update the software version Display Mode Display Normal To select Range Normal Reverse Contraste 47 To select R...

Страница 35: ...ctioning the side white leds are switch off or switch on When the machine ON YES The lights are ON NO The lights are OFF The lights are always OFF when the machine is OFF Mode exposition Mode expositi...

Страница 36: ...V 2 11 36 10 2 25 Alarm history 10 2 26 Password Access to the all complete menu Password Language Next step Acces only to steps marked Alarm history Next step To see the 10 next defaults in memory Al...

Страница 37: ...erature C Temperature C 117 87 78 90 81 93 85 120 87 78 90 81 93 85 123 87 79 90 82 93 85 125 87 79 90 82 93 85 To adjust the coffee temperature you can change the coffee boiler and group temperature...

Страница 38: ...ed between the programmed mini and max For example programmed value Min 0 80 ml s Max 1 20 ml s Position 1 flow between 0 80 ml s and 0 86 ml s Position 2 flow between 0 86 ml s and 0 91 ml s Position...

Страница 39: ...the display shows dose setting Press MENU again for ENTER Press the product button hot milk or milk foam The machine starts to heat the product At the same time the display shows the T value read insi...

Страница 40: ...Please make sure the USB stick does not contain any other file It must be empty Put the machine on stand by the display shows Insert the USB key in the mainboard Press the Menu button for 5 seconds a...

Страница 41: ...in When the upgrade is finished the display shows Switch OFF the machine Remove the USB key Switch ON the machine as soon as the graphic display shows Press the 3 following keys for 3 seconds When the...

Страница 42: ...ay o The machine asks for blind hold filter and the CONTI cleaning pill code n 466662 o Follow the instructions on the display o Repeat this procedure on each group Brush the filters in water containi...

Страница 43: ...12 Bars o Clean the nucleus of the solenoid inlet water boiler On the cold water valve block o Clean the both cold water valves cores On the pre brewing valve o Clean the pre brewing valve core On the...

Страница 44: ...brewing valve No 450033 On the coffee groups o Remove all the parts and uncork all the holes in the group head o Change the O ring nozzle No 403457 o Change the filter nozzle No 403458 o Change the so...

Страница 45: ...Temperature sensor for steam boiler RCCi Heating element group n i RCi Heating element n i for steam boiler RS Security relay RV i Adjustment of the display contrast groups n i SN Level probe SS Secur...

Страница 46: ...MONTE CARLO 11 2015 SOFT V 2 11 46 17 ELECTRIC DRAWING 17 1 CPU board...

Страница 47: ...MONTE CARLO 11 2015 SOFT V 2 11 47 17 2 Electrical power diagram for 400V 3L N PE...

Страница 48: ...MONTE CARLO 11 2015 SOFT V 2 11 48 17 3 Electrical power diagram for 230 V 1L N PE...

Страница 49: ...MONTE CARLO 11 2015 SOFT V 2 11 49 17 4 Connecting diagram 12 fuses box...

Страница 50: ...MONTE CARLO 11 2015 SOFT V 2 11 50...

Страница 51: ...MONTE CARLO 11 2015 SOFT V 2 11 51...

Страница 52: ...MONTE CARLO 11 2015 SOFT V 2 11 52...

Страница 53: ...MONTE CARLO 11 2015 SOFT V 2 11 53 17 5 Solid state relay interface for 400 V 3NAC...

Страница 54: ...MONTE CARLO 11 2015 SOFT V 2 11 54 17 6 Low voltage wiring...

Страница 55: ...MONTE CARLO 11 2015 SOFT V 2 11 55 18 HYDRAULIC SCHEME...

Страница 56: ...MONTE CARLO 11 2015 SOFT V 2 11 56...

Страница 57: ...e electronic board A22 Safety probe alarm low level Low level safety probe didn t detect water for more than 2 seconds boiler heating stopped Check the probe limestone Check the probe connection Check...

Страница 58: ...heck the flowmeter flashings Check the flowmeter connection Check the electronic board Check for clogged coffee group A29 Flow meter 3 time out alarm No flowmeter 3 pulse after 5 seconds Check the flo...

Страница 59: ...relay machine Nota Bene It is possible to retain the original cable 5x2 5 but in this case It is imperative to curb the power management 1 or 2 maximum if the machine is not used too much Power parame...

Страница 60: ...e r t I I B P 1 1 9 M C 9 8 0 0 7 M O N AC O C ed e x T l 37 7 9 3 1 0 4 3 4 3 F a x 3 7 7 9 3 10 4 3 4 4 h tt p ww w co nt i es p r e s so co m ht tp ww w co nt i sp a r ep a rt s co m E m ai l te c...