Edition 05/2021 - MC – Technical documentation - page
46
SACOME, CONFIDENTIAL Document, it is forbidden to duplicate or communicate this document without previous authorization.
14
MAINTENANCE OF MACHINES
DAILY MAINTENANCE
Clean the hot water outlet and the steam outlets with a scouring pad:
o
Use a needle to keep the diffuser outlets unclogged.
o
Then purge by opening the tap a few seconds.
Clean the drip tray and the basin, removing them from the machine.
Remove the filter-holder and clean the seal injection filter-holder with the brush.
Use the automatic process cleaning:
o
Push on the « clean » button
o
The automatic cleaning process of the group is started in 3 steps:
o
The process is shown on the display.
o
The machine asks for blind hold filter
and the CONTI cleaning pill code n°466662
o
Follow the instructions on the display.
o
Repeat this procedure on each group.
Brush the filters in water containing detergent:
o
In order to unclog the holes
o
Never use a needle or a flame.
For sanitary reasons, be sure to consume at least 2 liters of hot water per day.
HALF YEAR MAINTENANCE:
A kit n° 450200, for the following operation is available for sale.
For each group:
o
Remove the sprinkler, diffuser, and seal gasket.
o
Scrub the gasket groove and the supplying hole on the group head.
o
Clean the two parts of the diffuser. Clear all the holes with a needle.
o
Reassemble the 2 parts of the diffuser on the group head
o
Place NEW Filter gasket (No. 002711), and NEW sprinkler (No. 415684)
Remove and clean the level sensor and the safety sensor (limestone deposit).