background image

HD Ultra X Series Instructions     

 

 

 

5

 

 

 

 

 

8. 

Retighten the 3 x T10 locking 
screws to hold the Lid Cover 
down and in place. 

 

 

9. 

Press down on the Guide Plate 
until both ends lock in place to 
close. 

 

 

10. 

With the scanner powered up, 
and the OTAC pushed down, 
with the added +1 click on the 
ratchet, make sure the LED for 
the raised lid is off. 

 

 

11. 

If the LED does NOT go out 
when the OTAC is closed, then 
remove the rear panel to access 
the sensor, to make adjustments. 
Remove the T10 screws and lift 
the rear panel off from the back 
of the scanner. 

 

Содержание HD Ultra X Series

Страница 1: ...ing the Lid Latches at both ends 2 Use a cloth or similar to cover the gap in the lower chassis to prevent the e clip from falling into the chassis then remove the E clip using small flat screwdriver 3 Repeat for the right end again making sure to use a cloth to prevent the e clip falling into the chassis 4 Slide a piece of paper under the Guide Plate Hinge to prevent the T20 screw falling into th...

Страница 2: ...Repeat for the other end of the Guide Plate 6 Lift the OTAC and remove the brass spacers at both ends 7 Carefully push the Gas Piston off from the bracket making sure not to cause any damage 8 Repeat for the other end of the Guide Plate ...

Страница 3: ... the Top Lid Cover off from the chassis Replacing the OTAC Unit 1 When replacing the Guide Plate make sure the Gas Pistons go inside of the end plates 2 Position the Gas Piston over the pillars on the end plates at both ends 3 Lift the OTAC and refit the brass spacers at both ends ...

Страница 4: ...the long T20 screw Do this at both ends of the Guide Plate 5 Use an e clip insertion tool or pliers to refit the e clips over the Gas Piston bracket Make sure it is fully clicked in place Repeat at both ends 6 To refit the Lid Cover with the OTAC at its highest level position the Lid Cover back on the Guide Plate 7 Making sure the locating pins go into slots on the OTAC at both ends ...

Страница 5: ...lock in place to close 10 With the scanner powered up and the OTAC pushed down with the added 1 click on the ratchet make sure the LED for the raised lid is off 11 If the LED does NOT go out when the OTAC is closed then remove the rear panel to access the sensor to make adjustments Remove the T10 screws and lift the rear panel off from the back of the scanner ...

Страница 6: ...n the locking screw and move the sensor bracket up or down until the Lid LED goes out 13 Retighten the screw 14 Retest the LED but raising the OTAC and pressing down adding the 1 ratchet click If the LED is correctly setup still off then refit the rear cover Video Work Instruction http www training contex com OTAC ...

Отзывы: