Maintenance
7-9
Camera C: 3 flashes per period.
Before proceeding with CCD camera height adjustment, perform the
following for the camera that has the out of light error:
1. Turn the height adjustment screw eight turns clockwise.
2. Turn the scanner power off, and then on. If the error still shows,
turn the height adjustment screw sixteen turns counterclockwise.
3. Turn the scanner power off, and then on. If the error still shows
call maintenance to adjust the camera.
Note:
Camera-B is not user adjustable
After clearing the "Camera out of light error", you will need to perform
Camera Height Alignment and Calibration as described in previous
sections.