![Contemporary Research ICC1-IR Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/contemporary-research/icc1-ir/icc1-ir_product-manual_2656360009.webp)
Contemporary Research
9
ICC1-IR
Installation
Setting Device Number and Parameters (Device Mode)
Turn enclosure so the DIP switches are on the bottom
In the next step, you’ll need to set up the device number and operation parameters for the ICC1-IR. Notice that
the functions of the S1 and S2 switches change when you set the unit in Device mode.
1.
Make sure S2 Switch 6 is OFF (unit in Device mode).
2.
Set the
Device number
by turning on the switches that add up to the desired device number. For
example, for Device #259, turn on S1 switches 1 and 2 (3), S2 switch 1 (256)
Zone Switch Settings (S2
– right side)
To define the controller’s Zone, use the following pattern of switches ON for the S2 DIP.
Zone
Value
1
2
3
4
256
512
1024 2048
1
256
X
2
512
X
3
768
X
X
4
1024
X
5
1280
X
X
6
1536
X
X
7
1792
X
X
X
8
2048
X
9
2304
X
X
10
2560
X
X
11
2816
X
X
X
12
3072
X
X
13
3328
X
X
X
14
3584
X
X
X
15
3840
X
X
X
X
Содержание ICC1-IR