![Contemporary Research ICA-FT6 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/contemporary-research/ica-ft6/ica-ft6_product-manual_2656348013.webp)
iC-Net Setup and Control
RS-232 Terminal
Employ standard Windows Terminal program through the ICC-HE Program port, set to appropriate COM port
and RS-232 parameters, default is, 8 data bits, no parity, 1 stop bit.
Command
Code Description
Commands shown in ASCII and end with carriage return (Decimal 13, Hex $0D,
or Enter key.
Response displays * character to signify end of characters, or times out if no
characters are received after 2 seconds.
Tip: Just hit Enter to repeat any Terminal command.
Echo Enable
EN
>EN — Enables character echo so you can see typed characters on screen.
Echo Disable
EF
>EF — Disables terminal character display (default).
Version VE
>VE — Displays HE software version.
Reset Z!
>Z! — Performs system reset.
iC ToolKit Software
Most of the general setup and testing operations can be performed through iC Toolkit, including setting the
system Tune Rings, entering Channel Labels, changing device numbers, commanding all devices to show STA
and FTA ID, and system troubleshooting.
RS-232 Control System Protocol
The remaining setup and control operations can be performed through the control system itself. By creating
commands sent on power-up (see iC-Net Zones and System Map) the control system can define basic system
operation, including Channel Labels (TN command), Operating Parameters (TM), Tuning Rings (TR), and ICA-
FT6 setup using the UX command. By addressing commands to the global device number, 4095, all devices can
be updated and reset at the same time.