Contemporary Controls USB22 Series Скачать руководство пользователя страница 4

 

TD040900-0IJ 

4

 

RJ-45 Connector Pin Assignments 

 

4000 

485 

TB5 

 4 

Line 

Line –  Line – 

 5 

Line 

Line +  Line + 

(All other pins are unused.)

 

Screw Terminal Pin Assignments 

 

4000 

485 

 1 

Line 

Line – 

 2 

Shield  Shield 

 3 

Line 

Line + 

Mechanical 

 

Figure 3 — USB22-CXB Dimensions 

 

ELECTROMAGNETIC COMPATIBILITY 

All USB22 models comply with Class A radiated and conducted emissions 
as defined by EN55022 and CFR 47, Part 15.  This equipment is intended 
for use in non-residential areas. 

Warning 

This is a Class A product as defined in EN55022.  In a domestic environment 
this product may cause radio interference in which case the user may be 
required to take adequate measures. 

Figure 1 — RJ-45 Connector

 

Figure 2 — 3-pin Connector

 

(The case dimensions shown below are valid for all models.) 

Содержание USB22 Series

Страница 1: ...SB 1 1 devices The NIM is powered from a computer USB port or a USB hub Models exist for the most popular ARCNET physical layers A USB cable is also provided NOTE The USB22 Series of NIMs are for user...

Страница 2: ...se without the prior written permission of Contemporary Control Systems Inc 2431 Curtiss Street Downers Grove Illinois 60515 USA Tel 1 630 963 7070 Fax 1 630 963 0109 E mail info ccontrols com Web www...

Страница 3: ...temperature 0 C to 60 C Storage temperature 40 C to 85 C Humidity 10 to 95 non condensing ARCNET Data Rates Shipping Weight 1 lb 45 kg Compatibility ANSI ATA 878 1 USB 1 1 and USB 2 0 Regulatory Comp...

Страница 4: ...Y All USB22 models comply with Class A radiated and conducted emissions as defined by EN55022 and CFR 47 Part 15 This equipment is intended for use in non residential areas Warning This is a Class A p...

Страница 5: ...ed by the suffix 4000 485 CXB or TB5 separated from the main number by a hyphen CXB Coaxial Bus Generally two types of coaxial cables are used with ARCNET RG 62 u and RG 59 u RG 62 u is recommended be...

Страница 6: ...ring remains consistent throughout the network All phase A signals on NIMs and hubs must connect together The same applies to phase B Refer to Figures 1 and 2 for connector wiring Termination If the N...

Страница 7: ...AC coupled transceivers operate only at 1 25 2 5 5 0 and 10 Mbps whereas DC coupled transceivers function over all standard data rates Two models support AC coupled EIA 485 segments The USB22 4000 pr...

Страница 8: ...over repair of products that have been damaged by abuse accident disaster misuse or incorrect installation User modification may void the warranty if the product is damaged by the modification in whic...

Отзывы: