Contemporary Controls BASRT-B Скачать руководство пользователя страница 2

 

TD071200-0IC 

2

 

Trademarks 

Contemporary  Controls,  ARC  Control,  ARC  DETECT,  EXTEND-
A-BUS,  RapidRing,  and  CTRLink  are  trademarks  or  registered 
trademarks of Contemporary Control Systems, Inc.  Specifications 
are subject to change without notice.  Other product names may be 
trademarks  or registered trademarks  of their respective companies.  
BACnet is a registered trademark of the American Society of Heating, 
Refrigeration, and Air-Conditioning Engineers, Inc. (ASHRAE). 

TD071200-0IC  6 August 2009 

Copyright 

©  Copyright  2009  by  Contemporary  Control  Systems,  Inc.    All 
rights  reserved.    No  part  of  this  publication  may  be  reproduced, 
transmitted, transcribed, stored in a retrieval system, or translated 
into any  language  or computer language,  in any form  or by any 
means, electronic, mechanical, magnetic, optical, chemical, manual, 
or otherwise, without the prior written permission of: 

Contemporary Control Systems, Inc. 

2431 Curtiss Street 
Downers Grove, Illinois 60515 USA 
Tel: 

1-630-963-7070 

Fax: 

1-630-963-0109 

E-mail:  [email protected] 
Web: 

www.ccontrols.com 

Contemporary Controls (Suzhou) Co. Ltd 

11 Huoju Road, Science & Technology Park 
New District, Suzhou, PR China 215009 
Tel: 

+86-512-68095866 

Fax: 

+86-512-68093760 

E-mail:  [email protected] 
Web: 

www.ccontrols.com.cn 

Contemporary Controls Ltd 

Sovereign Court Two, UWSP 
Sir William Lyons Road 
Coventry, CV4 7EZ, UK 
Tel: 

+44 (0)24 7641 3786 

Fax: 

+44 (0)24 7641 3923 

E-mail 

[email protected] 

Web: 

www.ccontrols.co.uk 

Contemporary Controls GmbH 

Fuggerstraße 1 B 
04158 Leipzig, Germany 
Tel: 

+49 0341 520359 0 

Fax: 

+49 0341 520359 16 

E-mail 

[email protected] 

Web: 

www.ccontrols.de 

Disclaimer 

Contemporary  Control  Systems,  Inc.  reserves  the  right  to  make 
changes in the specifications of the product described within this 
manual  at  any  time  without  notice  and  without  obligation  of 
Contemporary Control Systems, Inc. to notify any person of such 
revision or change. 

Содержание BASRT-B

Страница 1: ...BASRT B BACnet IP to MS TP Router Installation Guide TD071200 0IC For Firmware Versions 1 x...

Страница 2: ...r written permission of Contemporary Control Systems Inc 2431 Curtiss Street Downers Grove Illinois 60515 USA Tel 1 630 963 7070 Fax 1 630 963 0109 E mail info ccontrols com Web www ccontrols com Cont...

Страница 3: ...Connectors 6 EIA 485 Bias and Termination Jumpers 6 Mechanical 6 3 Power 7 POWER SUPPLY PRECAUTIONS 7 Limited Power Sources 10 4 LEDS 10 5 Operation 11 MS TP Port 11 Ethernet Port 12 IP Address Reset...

Страница 4: ...n pair usage to whatever is needed by the attached equipment Thus only a straight through CAT5 cable is needed for hook up The BASRT B features a user accessible switch to reset the IP address subnet...

Страница 5: ...0 76800 MS TP node limit 254 devices total 31 full load devices per segment MS TP LED flashing green receive valid activity Ethernet LED green 100 Mbps yellow 10 Mbps flashing activity Regulatory Comp...

Страница 6: ...tor Aux This connector is only used for firmware upgrades EIA 485 Bias and Termination Jumpers U Install jumper to apply pull up bias T Install jumper to terminate bus D Install jumper to apply pull d...

Страница 7: ...wering devices can present hazards Read the text on the following page carefully POWER SUPPLY PRECAUTIONS Internally the router utilizes a half wave rectifier and therefore can share the same AC power...

Страница 8: ...minal of the source to either the HI or the HIB input and the negative terminal to COM on the router Reversing polarity to the router will not damage the router If shielded cable is used it is recomme...

Страница 9: ...with Shared Power Source For MS TP devices that use a power source separate from the BASRT B see Figure 9 for proper 2 wire bus connections and Figure 10 for proper 3 wire bus connections Figure 9 2 w...

Страница 10: ...he wiring system between the load side of a Class 2 power source and the connected equipment For AC or DC voltages up to 30 volts the power rating of a Class 2 power source is limited to 100 VA The tr...

Страница 11: ...to the other devices on the MS TP network This is accomplished by pin SC The differential pair is labelled and and corresponds to the same designations in the BACnet MS TP standard This requires a thr...

Страница 12: ...led at the end of a segment remove all the jumpers and install 120 at the far end of the bus Ethernet Port This port offers a shielded RJ 45 connector Through auto negotiation and Auto MDIX it automat...

Страница 13: ...on and a connection to the MS TP network To configure the router attach it to a computer with an Ethernet connection and a standard web browser For initial configuration the PC chosen for the procedur...

Страница 14: ...TD071200 0IC 14 Figure 13 Steps for Changing the IP Address of the PC Used for Setup On some systems this option is My Network Places...

Страница 15: ...in Figure 14 using Windows Internet Explorer Figure 14 Router Configuration Page with Default Values Each configuration parameter is explained on the following pages When save changes is selected the...

Страница 16: ...network within the BACnet internetwork must have a unique number This includes the BACnet IP and MS TP sides of the BASRT B Do not use addresses 0 or 65535 since these addresses are reserved IP Addres...

Страница 17: ...t Value 127 Only master nodes participate in the MS TP token passing process The highest master MAC address in decimal in the MS TP network is 127 and you should use 127 if you are unsure of other MS...

Страница 18: ...same baud rate On power up the router checks for other masters if finding none it begins token passing at which point autobauding devices will adjust to the router s baud rate MS TP Tolerance Default...

Страница 19: ...oes not cover repair or replacement This warranty in no way warrants suitability of the product for any specific application IN NO EVENT WILL CC BE LIABLE FOR ANY DAMAGES INCLUDING LOST PROFITS LOST S...