3. External Connection
30
VNA-300M-PCI
Connecting the Reference Clock Input Signal
This section provides an example of using an SMA cable to connect the reference clock input signal.
Use a commercially available SMA cable to connect the external device to the clock.
The input is AC-coupled. You can apply an external reference clock with a frequency of 10MHz.
To switch between the internal reference clock and an external reference clock, use the software.
BOARD
CLK
Target
Reference
CLK (IN)
Ground
Shield cable
Figure 3.9. Connecting the Reference Clock Input
CAUTION
-
When you have specified external reference clock input, perform program initializations with the
input from the external reference clock applied.
-
When you have specified external reference clock input, if the applied reference clock does not
meet the input specifications, the product will automatically switch to the internal clock.
Reference
For the input specifications of the external reference clock, refer to "Reference clock input" under
"Hardware specification" in "Chapter 6 About Hardware".