![Contec SIS-8601-LVA Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/contec/sis-8601-lva/sis-8601-lva_user-manual_2656017045.webp)
5 Software Utilities
38
SIS-8601-LVA
5.6. Watch-Dog-Timer (WDT) Setting
WDT is widely used for industry application to monitoring the activity of CPU.
Application software depends on its requirement to trigger WDT with adequate timer setting.
Before WDT time out, the functional normal system will reload the WDT. The WDT never time
out for a normal system. The WDT will not be reload by an abnormal system, then WDT will
time out and reset the system automatically to avoid abnormal operation.
SIS-8601-LVA supports 15 levels watchdog timer by software programming I/O ports.
Write any value to I/O address 0441H will disable Watch-Dog-Timer. Write setting code (please
reference to WDT Setting Table) to I/O 0443h will re-load WDT.
Below is an assembly program example for disable and load of WDT.
MOV DX,0441H REM Write any value to 0441H, disable WDT
OUT DX,AX;
MOV AX,0001H REM set WDT timer = 28 Sec
MOV DX,0443H
OUT DX,AX REM trigger WDT with timer setting
VALUE
TIMER
VALUE
TIMER
VALUE
TIMER
VALUE
TIMER
0
30 Sec.
4
22 Sec.
8
14 Sec.
C
6 Sec.
1
28 Sec.
5
20 Sec.
9
12 Sec.
D
4 Sec.
2
26 Sec.
6
18 Sec.
A
10 Sec.
E
2 Sec.
3
24 Sec.
7
16 Sec.
B
8 Sec.
F
Don’t Set
Note:
The timer’s intervals have a tolerance of ±5%.
Содержание SIS-8601-LVA
Страница 15: ...1 Introduction 8 SIS 8601 LVA...
Страница 37: ...3 Jumper Setting 30 SIS 8601 LVA...
Страница 41: ...4 CPU card Resources 34 SIS 8601 LVA...
Страница 89: ...6 BIOS Setup 82 SIS 8601 LVA...