Ver.1.00
RRY-16CX-USB
2
Item Specification
No. of Output Channels
16 channels (independent common)
Output Format
Reed Relay (1a, make) Output
Max. rating capacity
2A 125V(AC), 2A 30V(DC) (load resister)
Max. permitted
voltage
125V (Max.) *1, *2
Max. Carry Current
2A (Max.)
Contact resistance
(Initial state)
30m
Ω
or less
Operating time
(At the time of ON)
Within 7ms
Recovery time
(At the time of OFF)
Within 6ms
Mechanical Life
Expectancy
20,000,000 operations min or more Switching times :
180/min
Electrical lifetime
100,000 operations min or more Switching times :
20/min
Relay
Contact
Spec.
Relay Type
PCN-105D3MHZ
USB section
Bus specification
USB Specification 2.0/1.1 standard
USB transfer rate
12Mbps (Full-speed), 480Mbps (High-speed) *3
Power supply
Self-power
Common section
Number of terminals used at
the same time
127 terminals (Max.) *4
Dielectric strength
250Vrms
Current consumption (Max.)
5VDC 600mA
Operating conditions*5
0 - 50ºC, 10 - 90%RH (No condensation)
Allowable distance of signal
extension
Approx. 50m (depending on wiring environment)
Physical dimensions (mm)
180(W) x 140(D) x 34(H) (No protrusions)
Weight
400g (Not including the USB cable, attachment)
Connector
37-pin D-SUB, female connector
DCLC-J37SAF-20L9E(mfd. by JAE) or equivalent to it
Attached cable
USB cable 1.8m
*1 Please exceed neither max. permitted voltage nor max. rating capacity of the use relay
when using it by the voltage that exceeds 30VDC. Doing so can cause a malfunction.
*2 The potential difference between channels must not exceed 125V in the maximum.
Doing so can cause a malfunction.
*3 This depends on the PC environment used (OS and USB host controller).
*4 As a USB hub is also counted as one device, you cannot just connect 127 USB unit.
*5 To suppress the heating, ensure that there are spaces for ventilation (about 5cm) around
this product.
Windows version of digital I/O driver API-DIO(WDM)
[Stored on the bundled CD-ROM driver library API-USBP(WDM)]
It is the library software, and which supplies command of
hardware produced by our company in the form of standard
Win32 API function (DLL). Using programming languages
supporting Win32API functions, such as Visual Basic and
Visual C++ etc., you can develop high-speed application
software with feature of hardware produced by our company.
In addition, you can verify the operation of hardware using
Diagnostic programs.
< Operating environment >
OS
Windows 7, Server 2008, Vista, XP,
Server 2003, 2000, Me, 98
Adaptation language Visual Basic, Visual C++, Visual C#,
Delphi, C++ Builder
You can download the updated version from the CONTEC’s
Web site (http://www.contec.com/product/device/apiusbp/).
For more details on the supported OS, applicable language
and new information, please visit the CONTEC’s Web site.
Data acquisition VI library for LabVIEW VI-DAQ
(Available for downloading (free of charge) from the CONTEC web site.)
This is a VI library to use in National Instruments LabVIEW.
VI-DAQ is created with a function form similar to that of
LabVIEW's Data Acquisition VI, allowing you to use various
devices without complicated settings.
See http://www.contec.com/vidaq/ for details and download of
VI-DAQ.
Cable (Option)
Flat cable with both-ends 37-pin D-SUB connector
: CB37P-1.5 (1.5m)
: PCB37P-3 (3m)
: PCB37P-5 (5m)
Shield cable with both-ends 37-pin D-SUB connector
: PCB37PS-0.5P (0.5m)
: PCB37PS-1.5P (1.5m)
: PCB37PS-3P (3m)
: PCB37PS-5P (5m)
Flat cable with one-end 37-Pin D-SUB connector
: PCA37P-1.5 (1.5m)
: PCA37P-3 (3m)
: PCA37P-5 (5m)
Shield cable with one-end 37-pin D-SUB connector
: PCA37PS-0.5P (0.5m)
: PCA37PS-1.5P (1.5m)
: PCA37PS-3P (3m)
: PCA37PS-5P (5m)
Connector (Option)
37pin D-SUB(male) connector Five-piece set
:
CN5-D37M
Accessories (Option)
Screw Terminal (M3 x 37P)
: EPD-37A *1*2
Screw Terminal (M3.5 x 37P)
: EPD-37 *1
General Purpose Terminal (M3 x 37P) : DTP-3A *1
Screw Terminal (M2.6 x 37P)
: DTP-4A *1
USB I/O Unit Bracket for X Series
: BRK-USB-X
AC adapter (input : 90 - 264VAC, output : 5VDC 2.0A)
:POA200-20-2
*3
AC-DC power supply unit(input: 85 - 132VAC, output: 5VDC 3.0A)
:
POW-AC13GY
AC-DC power supply unit(input: 85 - 264VAC, output: 5VDC 2.0A)
:
POW-AD22GY
DC-DC power supply unit(input: 10 - 30VDC, output: 5VDC 3.0A)
:
POW-DD10GY
DC-DC power supply unit(input: 30 - 50VDC, output: 5VDC 3.0A)
:
POW-DD43GY
*1 PCB37P or PCB37PS optional cable is required separately.
*2 “Spring-up” type terminal is used to prevent terminal screws from falling off.
*3 It is the same as the one appended to the product. Please buy it necessary for
maintenance.
*
Check the CONTEC’s Web site for more information on these options.
- Unit [RRY-16CX-USB] …1
- AC adapter …1
- AC Cable (for 125VAC) …1
- USB cable (1.8m) …1
- USB cable attachment on the main unit’s side
(For Mini B connector side) …1
- Clamps for prevention of cable on the main unit’s side …1
- CD-ROM *1 [API-USBP(WDM)] …1
- First step guide … 1
- Power connector MC1,5/3-ST-3,5 …1
- Ferrite core …1
*1 The CD-ROM contains the driver software and User’s Guide (this guide)
Packing List
Cable & Connector
Support Software
Accessories
Specification
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de