2. Setup
14
EAD-CE-EC
Setup Troubleshooting
Please confirm followings when EAD-CE-EC does not work.
Symptoms and Actions
The chassis won’t be turned on.
a. Make sure that the power cable has been connected correctly.
b. Make sure that the power supplies of the PC and expansion chassis are on.
c. Make sure that you have followed the procedure in Chapter 2.
d. Even though the chassis is still not turned on, check whether it is turned on with no board installed.
If the chassis is turned on with no board installed, check the total current consumption by the
installed boards. The total current consumption must not exceed the power capacity of the
expansion chassis.
No PCI board on the expansion chassis is detected.
e. Make sure that the ExpressCard [BUS-PC-EC] has been connected correctly.
f.
Make sure that the connection cable [CB-CE1] has been installed correctly. When connecting the
connection cable to the main chassis, insert the connector until it clicks into place.
g. Make sure that the POWER LED on the expansion chassis is turned on.
The photo is of the
EAD-CE-EC + ECH-PCI-CE-H2B.
g
e
a
b