Appendix
—
CPSN-SSI-4C Reference Manual (Hardware)
—
30
—
1.
Specifications
Function Specifications
Item
CPSN-SSI-4C
Input type
Differential input
Input channel
4ch
Resolution
24-bit (1/1024 °C)
Conversion speed*1
251ms (Measure four thermocouples and one cold junction sensor per
channel)
Buffer memory
The latest data only
Conversion start condition
Constant update
Compatible thermocouple sensor J(IEC 60584-1), K(IEC 60584-1), E(IEC 60584-1),
N(IEC 60584-1), R(IEC 60584-1), S(IEC 60584-1), T(IEC 60584-1)
Conversion tolerance
Thermocouple type K, J, E, N, T:
Within ± [0.3°C + Measured temperature×0.12% (0°C or higher) or
1% (0°C or lower)
Thermocouple type R, S:
Within ± [1.2°C + Measured temperature×0.12%]
Cold junction sensor
Integrated
Cold junction tolerance *2*3
Within 3.6°C (Vertical installation (Installation angle 0°))
Isolation
Bus isolation
Isolation withstand voltage
500VDC
Connector
2 pieces 3.81mm pitch 10-pin terminal
Applicable wire
AWG28 - 16
LED
4 (Green)
Electricity consumption
5V 0.15A (Max.)
3.3V 0.05A (Max.)
Physical dimensions (mm)
15.6(W)×52.6(D)×84(H) (No projection included)
Weight
50g
*1 It is the conversion time of the measurement value. Communication time is not included.
*2 It is the measured value under the condition of wind speed of 0-0.5m/s in the thermostatic bath.
*3 The cold junction tolerance is within 4.6 ° C when the product is installed in the orientation other
than vertical installation (Installation angle 0 °).
Installation orientation requires software command to change the settings. (Default: vertical
installation)