6. About Hardware
AO-1616L-LPE, AO-1608L-LPE
67
Control Signal Timings for Counter
Figures 6.6, 6.7, and Table 6.4 show the control signal timings for the analog input function.
Figure 6.6. Timing Chart of Counter Input Signal
Figure 6.7. Timing Chart of Counter Output Signal (Pulse output)
Table 6.4. Control Signal Timings
Parameter
Symbol Time
Unit
Set up time of counter input signal (Rising edge)
t
SRC
100
nsec
Hold time of counter input signal (Rising edge)
t
HRC
100
nsec
Pulse width of counter output signal
t
PSC
1000
nsec
The times listed in Table 6.4 are for standard operating conditions.
Counter Up Pulse Input
t
HRC
t
SRC
Counter Compair Output
t
PSC
CAUTION
Содержание AO-1608L-LPE
Страница 7: ...vi AO 1616L LPE AO 1608L LPE ...
Страница 15: ...1 Before Using the Product 8 AO 1616L LPE AO 1608L LPE ...
Страница 33: ...2 Setup 26 AO 1616L LPE AO 1608L LPE ...
Страница 39: ...3 External Connection 32 AO 1616L LPE AO 1608L LPE ...