Ver.1.05
AIO-160802LI-PE
2
Specification
Item
Specifications
Analog input
Isolated specification
Bus-Isolated
Input type
Single-Ended Input
Number of input channels
8ch
Input range
Bipolar
±
10V
Absolute max. input
voltage
±
20V
Input impedance
1M
Ω
or more
Resolution
16bit
Non-Linearity error *1*2
±
16LSB
Conversion speed
10
µ
sec/ch*3 [100KSPS]*4
Buffer memory
1k Word
Conversion start trigger
Software / external trigger
Conversion stop trigger
Number of sampling times / external trigger/software
External start signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External stop signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External clock signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Analog output
Isolated specification
Bus-Isolated
Number of output channels
2ch
Output range
Bipolar
±
10V
Absolute max. input
currency
±
5mA
Output impedance
1
Ω
or less
Resolution
16bit
Non-Linearity error *1
±
5LSB
Conversion speed
10
µ
sec [100KSPS]*4
Buffer memory
1k Word
Conversion start trigger
Software / external trigger
Conversion stop trigger
Number of sampling times / external trigger/software
External start signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External stop signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
Digital filter (1msec can be selected by software)
External clock signal
Isolation TTL-level (Rising or falling edge can be selected by
software)
*1: The non-linearity error means an error of approximately 0.1% occurs over the maximum
range at 0
°
C and 50
°
C ambient temperature.
*2: At the time of the source use of a signal which built in the high-speed operational amplifier.
*3: The required time is indicated in the analog to digital translation of one channel. When AD of
two or more channels is converted, time of the a few minutes of the channel is necessary.
Conversion time = Number of conversion channelsx10
µ
sec
*4: SPS = Samplings Per Second. The number of data that can be converted in one second is
shown.
Dimensions
Support Software
Windows version of analog I/O driver API-AIO(WDM)
[Stored on the bundled disk driver library API-PAC(W32)]
The API-AIO(WDM) is the Windows version driver library software that
provides products in the form of Win32 API functions (DLL). Various
sample programs such as Visual Basic and Visual C++, etc and
diagnostic program *1useful for checking operation is provided.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Linux version of analog I/O driver API-AIO(LNX)
[Stored on the bundled disk driver library API-PAC(W32)]
The API-AIO(LNX) is the Linux version driver software which provides
device drivers (modules) by shared library and kernel version. Various
sample programs of gcc are provided.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Data Logger Software C-LOGGER
[Stored on the bundled disk driver library API-PAC(W32)]
C-LOGGER is a data logger software program compatible with our
analog I/O products. This program enables the graph display of
recorded signal data, zoom observation, file saving, and dynamic
transfer to the spreadsheet software “Excel”. No troublesome
programming is required.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Data Acquisition library for MATLAB ML-DAQ
(Available for downloading (free of charge) from the CONTEC web
site.)
This is the library software which allows you to use our analog I/O
device products on MATLAB by the MathWorks. Each function is offered
in accordance with the interface which is integrated in MATLAB’s Data
Acquisition Toolbox.
For more details on the supported OS, applicable language and new
information, please visit the CONTEC’s Web site.
Data acquisition VI library for LabVIEW VI-DAQ
(Available for downloading (free of charge) from the CONTEC web
site.)
This is a VI library to use in National Instruments LabVIEW.
VI-DAQ is created with a function form similar to that of LabVIEW's
Data Acquisition VI, allowing you to use various devices without
complicated settings.
For more details on the library and download of VI-DAQ, please visit
the CONTEC’s Web site.
Packing List
Board [AIO-160802LI-PE] …1
First step guide … 1
Disk *1 [API-PAC(W32)] …1
Warranty Certificate …1
Serial Number Label …1
*1 The bundled disk contains the driver software and User’s Guide.
The standard outside dimension (L) is
the distance from the end of the board to
the outer surface of the slot cover.
[mm]
169.33(L)
11
0
.1
8
(H)
Item
Specifications
Digital I/O
Number of input channels
Isolated input 4ch (TTL-level positive logic)
Number of output
channels
Isolated input 4ch (TTL-level positive logic)
Counter
Number of channels
1ch
Counting system
Up count
Max. count
FFFFFFFFh (Binary data,32bit)
Number of external inputs
2 Isolation TTL-level (Gate/Up)
Gate (positive logic/level), Up (Rising edge)
Number of external
outputs
1 Isolation TTL-level Count match output (positive logic, pulse
output)
Response frequency
1MHz (Max.)
Common section
I/O address
64 ports
Interruption level
Errors and various factors, One interrupt request line as INTA
Connector
10250-52A2JL[3M]
Power consumption
3.3VDC 1100mA (Max.)
Operating condition
0 - 50
°
C, 10 - 90%RH (No condensation)
Bus specification
PCI Express Base Specification Rev. 1.0a x1
Dimension (mm)
169.33 (L) x 110.18(H)
Weight
120g
PLUG-IN Electronic GmbH • Am Sonnenlicht 5 • 82239 Alling • Tel.: +49 (0) 8141 3697-0 • [email protected] • www.plug-in.de