P90 Pallet racking | Installation manual
Upright installation
Vertical back stop
NOTE! The profile must be
installed in order for the
locking/clamp to turn parallel
with the length of the racking.
In general the back stop begins
at the lower beam level. The
stop can begin at floor level and
is then anchored into the floor
with a concrete screw M10.
Upright protector
To be installed with a free clearance of min.
50 mm between upright and protector
peak, inside.
The protector is anchored in concrete floor using
concrete screw M10.
50 mm
Self tapping screw
M6SF-TT M6x20
Screw
M10x25
Concrete screw
M10
Self tapping screw
M6SF-TT M6x20
I beam
Box beam
Self tapping screw
ST 4,8x25
In case of Box beam
you place the g pro-
tector at the pallet
fork tunnel
In case of I beam you can choose any position of the g
protector behind the pallet
Nut
M10 Nyloc