P90 Pallet racking | Installation manual
Guidelines bracing
Tox beam upright depth
Box beam upright depth
Bracing/total length
Short side handling
depth 1037 mm
Long side handling
depth 737 mm
Short side handling
depth 1100 mm
Long side handling
depth 800 mm
1 - Horizontal
L=
967 mm
667 mm
1030 mm
730 mm
2 - Diagonal
L=
1144 mm
908 mm
1198 mm
954 mm
3 - Diagonal
L=
1264 mm
1056 mm
1313 mm
1096 mm
Upright installation
Uprights
Installation order:
Place the uprights with the
openings facing each other.
Install the horizontal and
diagonal bracing, starting in 3rd
slot (114 mm) from the bottom
(see bracing guidelines below).
Then install the foot plates in
lower slot (14 mm). Use screw
M10x70 mm and nut M10.
Make sure that all bolts are
well tightened.
h=7000
3
3
3
3
2
2
2
2
2
2
1
h=6500
3
3
3
3
2
2
2
2
2
1
h=6000
3
3
2
2
2
2
2
2
2
1
h=5500
3
3
2
2
2
2
2
2
1
h=5000
2
2
2
2
2
2
2
2
1
h=4500
2
2
2
2
2
2
2
1
h=4000
3
2
2
2
2
2
1
h=3500
3
2
2
2
2
1
h=3000
3
3
2
2
1
h=2500
3
3
2
1
h=2000
2
2
2
1
86
800
800
800
800
600
600
600
600
600
600
114
186
800
800
800
800
600
600
600
600
600
114
86
800
800
600
600
600
600
600
600
600
114
186
800
800
600
600
600
600
600
600
114
86
600
600
600
600
600
600
600
600
114
186
600
600
600
600
600
600
600
114
86
800
600
600
600
600
600
114
186
800
600
600
600
600
114
86
800
800
600
600
114
186
800
800
600
114
86
600
600
600
114
First and last bracing
with spacer (red)
Other bracing
A
A
A
A
A
B
B
B
B
B
B
B
B