2
Temperature can be
GLVSOD\HGLQ
C or
F.
This can be changed
by SW1.
Heating status symbol:
Solid -
heating active
not shown
- heating inactive
Temperature not flashing : indicating room temperature
Temperature flashing : indicating set temperature when using UP or DOWN buttons
Radio transmit symbol –
will
flash every time a signal is sent.
SLVT
Wireless
Controller
The SLVT controller can control an unlimited number of heaters. The controller has 2 operating modes. It has to be
set to the required mode prior to the installation by using the switches located at the back of the controller.
Please read this guide carefully and retain for future use and maintenance.
Installation and User Guide
1. Getting to know your SLVT wireless controller
In timer mode, switch 3 or 4 must be in the ‘ON’ position. This mode allows for 3 different
settings which will alter the time period for each segment.
Switch 3 - Each time period represents 5 minutes.
Switch 4 - Each time period represents 15 minutes
Switch 3 & 4 - Each time period represents 30 minutes
2. Temperature and Timer Mode
For timer mode, the switches are set as shown below.
Controller functionality in timer mode:
In timer mode, the controller acts as a 4 stage run-back timer. When the controller is in stand-by mode and button is
pressed, the first indicator segment will light up green and heating is activated. When pressed again the second segment
will light up and so on. Each segment is representing a time period that is selected when setting the switches.
In the example below, the only switch in the ‘ON’ position would be number 3. The button would be pressed four times to
activate four 15-minute segments resulting in the heater staying on for 1 hour. At the end of the last time period, the light
indicators will be red for 4 seconds and then go off. The controller is now in stand-by mode.
If the timer mode is not selected, then the user will need to press the ON button again to deactivate the heating.
20 MINS
15 MINS
10 MINS
5 MINS
WARNINGS
·
Do NOT handle the appliance with wet hands.
·
Do NOT use the appliance in workshops or rooms with high dust
exposure.
·
Do NOT cover or restrict any aperture.
·
Do NOT use the appliance if damaged.
·
Do NOT leave the appliance unattended where young children
are present.
·
Ensure that nothing is pushed into any aperture of this controller.
·
Operating temperature range -10 to +40ºC.