5.1 Models for wireless controls
The wireless controlled model RAC1306RX can
be controlled by our CRX2 wireless controller. The
heater will not work without this controller. Each
controller has a unique identification code, it can
control an unlimited number of heaters and will not
interfere with other controllers within the building.
For more details please follow the instructions
supplied with the controller.
5. Operation.
4. Electrical Connections.
4.4 Electrical connections for wireless control models
To switch on the appliance and operate the blower,
depress the left-hand switch (marked “on/off”).
To change the fan speed use fan/boost switch.
When the heat 1 switch only (marked with a single
bar) is depressed the heat output is ⅓ of full heat.
RAC1306 - 2kW,RAC1309 - 3kW
When the heat 2 switch only (marked with a double
bar) is depressed the heat output is ⅔ of full heat.
RAC1306 - 4kW,RAC1309 - 6kW
When both heat switches are depressed the full heat
output is available.
RAC1306 - 6kW,RAC1309 - 9kW
Fig.13 ‘L’ and ‘N’ connections
Fig.14 Earth connection
L
N
5.2 Standard models
All standard RAC heaters are supplied with a re-
mote switch that gives the following functions;
On/off, fan, fan boost and heat.
For thermostatic control, a room thermostat with
6A switch rating maybe connected to the circuit.
The thermostat should be wired between the ter-
minal 1 and the heater remote switch.